Catalog Leica EM PACT2
EM PACT (old) Consumables & Accessories
| Code | Name Show all details | Qty |
|---|---|---|
| 16701955 | Insulated forceps
with insulation coating
|
|
| 16702120 | 4l Dewar for LN2
4l Dewar for LN2, to fill EM PACT.
|
|
| 16706845 | Optical Workstation
consisting of:
- 2x Eyepieces - Objective - S4 Stereozoom - LED Ringlight - Power cord - Base plate - Microscope carrier - Column |
|
| 16706849 | Sapphire discs
1.4mm diameter (100pcs).
|
|
| 16706852 | Ejector |
|
| 16706853 | Punching tool (including 2mm Allen key) |
|
| 16706854 | Flat Specimen Holder System N
-Loading device for flat holder (2pcs) -Sample punch-for producing specimen discs of 1mm diameter -Rubber sample punch support -Loading station -Unloading station -Torque wrench with Bit -Flat specimen pod (5pcs) -Flat specimen carrier 0.5mm thick, 1.2mm in diameter/200µm deep, gold plated (to prevent any toxic effects on sensitive specimens from the copper),100pcs -Sealing tube (50pcs) -Maintenance Kit -Forceps with straight tip -Forceps with insulation coating -Cryo transfer box for specimen carrier -Cryo-manipulator with M4 thread -Insulated container -Case for tools |
|
| 16706855 | Specimen Tube System STS EM PACT2
for use with EM PACT2 and EM PACT2 EM RTS
-Loading device for specimen tubes (2 pcs) -Punch for removing specimen tubes from holder -Specimen tube holder, loaded with specimen tubes (25 pcs) -Specimen tubes (100 pcs) -Needle for filling the specimen tubes (2 pcs) -Recycling kit, for fitting new specimen tubes into the specimen tube holder. -Cryo transfer box for specimen tube holder -Specimen tube peeler for lengthwise opening of tubes -Specimen tube insert for the LEICA FC-series cryochambers to hold the specimen tube for cryo sectioning -Cryo transfer box for specimen tubes -Insualted container -Forceps with straight tip -Special long forceps with insulated coating -Cryo-manipulator with M4 thread -Case for accessoires |
|
| 16706861 | Cutter for Flat Specimen Carrier
complete with Insulated container and holder for the FCS or FC6.
|
|
| 16706862 | Freeze Fracturing System
consisting of:
-maintenance Kit -Sealing tube (50pcs) -Cryo transfer box for biopsy carrier -Unloading station -Allen key for unloading -Cryo Manipulator M4 thread -Forceps with straight tip -Special long forceps with insulation coating -Loading station "FF" -Transfer slider -Torque wrench with bit -100 FF carriers, gold plated -100 FF rings -Flat specimen pod "N" (5pcs) -Loading device for Flat -Specimen holder (2pcs) |
|
| 16706866 | FF Carriers, gold plated (100pcs) |
|
| 16706867 | FFrings (100pcs) |
|
| 16706869 | Cellulose Capillary Tubes
Biological suspension is injected into the tubes via capillary action. Subsequent freeze substitution. 100 pieces. Polymer-Cellulose:
Fibre length - 50mm, Wall thickness (dry) 8 µm, Inner diameter (dry) 200 µm, Permeability (cut off) >5000 Dalton, pH range during operation 3 - 11. |
|
| 16706871 | Specimen tubes (100pcs) |
|
| 16706872 | Scoring wheels for tube cutter (1 pair) |
|
| 16706873 | Specimen tube holder, new (25pcs) |
|
| 16706878 | Sample punch , 1.2 mm dia |
|
| 16706887 | Biopsy Needle |
|
| 16706891 | Sealing tube for flat specimenholder
50pcs
|
|
| 16706892 | Re-usable sample punch (Dia. 1,5 mm)
for flat specimen holder.
|
|
| 16706896 | Biopsy carriers, gold plated (100pcs) |
|
| 16706897 | Flat Specimen Carrier, 1.2mm, 200µm deep
gold plated 0.5mm thick, 1.2mm in diameter, 200µm deep (100pcs).
|
|
| 16706898 | Flat Specimen Carrier, 1.5mm, 200µm deep
gold plated 0.5mm thick, 1.5mm in diameter, 200µm deep (100pcs)
|
|
| 16706899 | Flat Specimen Carrier, 1.2mm, 400µm deep
gold plated 0.6mm thick, 1.2mm in diameter, 400µm deep (100pcs)
|
|
| 16860165 | Mini fuses for 115V, 2AT, 10pcs |
|
| 16870071 | Torque wrench for flatspecimen holder |
|
| 16870072 | Bit, 2mm Allen key fortorque wrench |
|
| 16706836 | Cryopreparation box |
|
| 16706856 | Loading Station |
|
| 16706859 | Insert |
|
| 16860039 | Halogen bulb 5W/12V |
|
EM PACT2 Consumables & Accessories for Sapphire Disc System
| Code | Name Show all details | Qty |
|---|---|---|
| 16706849 | Sapphire discs
1.4mm diameter (100pcs).
|
|
| 16706897 | Flat Specimen Carrier, 1.2mm, 200µm deep
gold plated 0.5mm thick, 1.2mm in diameter, 200µm deep (100pcs).
|
|
| 16870071 | Torque wrench for flatspecimen holder |
|
| 16870072 | Bit, 2mm Allen key fortorque wrench |
|
| 16707896 | Finder Grids (100 pcs.) |
|
EM PACT2 Consumables & Accessories for Freeze Fracture System
| Code | Name Show all details | Qty |
|---|---|---|
| 16706866 | FF Carriers, gold plated (100pcs) |
|
| 16706867 | FFrings (100pcs) |
|
| 16870071 | Torque wrench for flatspecimen holder |
|
| 16870072 | Bit, 2mm Allen key fortorque wrench |
|
| 16707896 | Finder Grids (100 pcs.) |
|
| 16707831 | Freeze Fracture System 2
For use with EM PACT2 and EM PACT2 EM RTS
-Manual bayonet loading device (2 pcs) -Bayonet pod (5 pcs) -Loading station #FF# -Transfer slider -Torque wrench with bit -100 FF carriers, gold plated -100 FFrings -Cryo transfer box for Freeze Fracture carrier -Cryo Manipulator with M4thread -Fine forceps with straight tip -Forceps with insulation coating -Case for accessories |
|
EM PACT2 Consumables & Accessories for Microbiospy Transfer System
| Code | Name Show all details | Qty |
|---|---|---|
| 16706887 | Biopsy Needle |
|
| 16706896 | Biopsy carriers, gold plated (100pcs) |
|
| 16870071 | Torque wrench for flatspecimen holder |
|
| 16870072 | Bit, 2mm Allen key fortorque wrench |
|
| 16707896 | Finder Grids (100 pcs.) |
|
| 16707835 | Microbiopsy Transfer System MTS2
only for EM PACT2
-Manual bayonet loading device (2 pcs) -Bayonet pod (5 pcs) -Microbiopsy Gun -Biopsy needles (5 pcs) -Transfer station -Transfer leaf spring -Transfer slider -Torque wrench with bit -100 Biopsy carriers, gold plated -Cryo transfer box for biopsy carrier -Cryo Manipulator with M4thread -Fine forceps with straight tip -Forceps with insulation coating -Carrying case |
|
| 16707834 | Microbiopsy Transfer System RTS-MTS2
only for EM PACT2 EM RTS
-Bayonet pod (5 pcs) -Microbiopsy Gun -Biopsy needles (5 pcs) -Transfer station #MTS 2 for RTS# -Transfer leaf spring -Torque wrench with bit -100 Biopsy carriers, gold plated -Cryo transfer box for biopsy carrier -Cryo Manipulator with M4thread -Fine forceps with straight tip -Forceps with insulation coating -Carrying case |
|
EM PACT2 Consumables & Accessories for Flat Specimen Holder
| Code | Name Show all details | Qty |
|---|---|---|
| 16706861 | Cutter for Flat Specimen Carrier
complete with Insulated container and holder for the FCS or FC6.
|
|
| 16707836 | Cutter |
|
| 16706892 | Re-usable sample punch (Dia. 1,5 mm)
for flat specimen holder.
|
|
| 16706897 | Flat Specimen Carrier, 1.2mm, 200µm deep
gold plated 0.5mm thick, 1.2mm in diameter, 200µm deep (100pcs).
|
|
| 16706899 | Flat Specimen Carrier, 1.2mm, 400µm deep
gold plated 0.6mm thick, 1.2mm in diameter, 400µm deep (100pcs)
|
|
| 16870071 | Torque wrench for flatspecimen holder |
|
| 16870072 | Bit, 2mm Allen key fortorque wrench |
|
| 16707896 | Finder Grids (100 pcs.) |
|
| 16707830 | Flat Specimen System 2
For use with EM PACT2 and EM PACT2 EM RTS
-Manual bayonet loading device (2 pcs) -Bayonet pod (5 pcs) -Sample punch for specimen discs of 1.2 mm diameter -Rubber sample punch support -Loading station with slider -Torque wrench with bit -Flat specimen carrier 0.5mm thick, 1.2 mm in diameter/200µm deep, gold plated (100 pcs) -Fine forceps with straight tip. -Forceps with insulation coating. -Cryo transfer box for specimen carrier -Cyro-manipulator with M4 thread -Case for accessories |
|
EM PACT2 Consumables & Accessories for Specimen Tube System
| Code | Name Show all details | Qty |
|---|---|---|
| 16706869 | Cellulose Capillary Tubes
Biological suspension is injected into the tubes via capillary action. Subsequent freeze substitution. 100 pieces. Polymer-Cellulose:
Fibre length - 50mm, Wall thickness (dry) 8 µm, Inner diameter (dry) 200 µm, Permeability (cut off) >5000 Dalton, pH range during operation 3 - 11. |
|
| 16706871 | Specimen tubes (100pcs) |
|
| 16706873 | Specimen tube holder, new (25pcs) |
|
| 16706836 | Cryopreparation box |
|
EM PACT2 Consumables & Accessories for Live Cell
| Code | Name Show all details | Qty |
|---|---|---|
| 16706849 | Sapphire discs
1.4mm diameter (100pcs).
|
|
| 16907805 | Live Cell Kit
-Finder grid (100 pcs) -Live Cell carrier (100 pcs) -Sapphire Discs 1.4mm diameter (100pcs) |
|
| 16707895 | Insert for Microscopystage |
|
| 16707897 | Live Cell carrier (100 pcs) |
|
| 16707898 | Membrane carrier 1.5mm x 0.1mm, 100pcs |
|
| 16707899 | Membrane carrier 1.5mm x 0.2mm, (100pcs) |
|
EM PACT2 Accessories
| Code | Name Show all details | Qty |
|---|---|---|
| 16707825 | Rapid Transfer System for EM PACT2
Automatic high speed transfer device mounted on EM PACT2, consisting of:
-safety lid, -Platform for accessories -Rapid loader -RTS bayonet loading device for flat specimen pod (2 pcs) -Funnel for filling LN2 |
|
| 16707833 | Manual System for EM PACT2
-Specimen loading piston -safety cover |
|
| 16707827 | RTS bayonet loading device
for flat specimen pod (1pc).
|
|
| 16707828 | Manual bayonet loading device (1 pc) |
|
| 16707829 | Bayonet pod (1 pc) |
|
| 16706035 | Specimen tube holder
for tubes inserted in collet holder of the cryo ultramicrotome.
|
|
| 16707846 | Rapid loader CLEM
Modified Rapid loader designed to enable long term LM observation of the sapphire discs before the cryo-fixation takes place.
|
|