Applications Leica VT1200 S
Preclinical model of organotypic culture for pharmacodynamic profiling of human tumors
27 May 2011
Valentina Vaira, Giuseppe Fedele, Saumyadipta Pyne, Ester Fasoli, Giorgia Zadra, Dyane Bailey, Eric Snyder, Alice Faversani, Guido Coggi, Richard Flavin, Silvano Bosari, and Massimo Loda
Abstract
Predicting drug response in cancer patients remains a major challenge in the clinic. We have perfected an ex vivo, reproducible, rapid and personalized culture method to investigate antitumoral pharmacological properties that preserves the original cancer microenvironment. Response to signal transduction inhibitors in cancer is determined not only by properties of the drug target but also by mutations in other signaling molecules and the tumor microenvironment. As a proof of concept, we, therefore, focused on the PI3K/Akt signaling pathway, because it plays a prominent role in cancer and its activity is affected by epithelial–stromal interactions. Our results show that this culture model preserves tissue 3D architecture, cell viability, pathway activity, and global gene-expression profiles up to 5 days ex vivo. In addition, we show pathway modulation in tumor cells resulting from pharmacologic intervention in ex vivo culture. This technology may have a significant impact on patient selection for clinical trials and in predicting response to small-molecule inhibitor therapy. Click to read the entire report.
Preparation of Acute Hippocampal Slices from Rats and Transgenic Mice for the Study of Synaptic Alterations during Aging and Amyloid Pathology
20 May 2011
Diana M. Mathis1, Jennifer L. Furman2, Christopher M. Norris2, 3
1Graduate Center for Gerontology, University of Kentucky College of Public Health, 2Department of Molecular and Biomedical Pharmacology, University of Kentucky College of Medicine, 3Sanders-Brown Center on Aging, University of Kentucky College of Medicine
Abstract
The rodent hippocampal slice preparation is perhaps the most broadly used tool for investigating mammalian synaptic function and plasticity. The hippocampus can be extracted quickly and easily from rats and mice and slices remain viable for hours in oxygenated artificial cerebrospinal fluid.
Moreover, basic electrophysisologic techniques are easily applied to the investigation of synaptic function in hippocampal slices and have provided some of the best biomarkers for cognitive impairments. The hippocampal slice is especially popular for the study of synaptic plasticity mechanisms involved in learning and memory. Changes in the induction of long-term potentiation and depression (LTP and LTD) of synaptic efficacy in hippocampal slices (or lack thereof) are frequently used to describe the neurologic phenotype of cognitively-impaired animals and/or to evaluate the mechanism of action of nootropic compounds. This article outlines the procedures we use for preparing hippocampal slices from rats and transgenic mice for the study of synaptic alterations associated with brain aging and Alzheimer's disease (AD)1-3.
Use of aged rats and AD model mice can present a unique set of challenges to researchers accustomed to using younger rats and/or mice in their research. Aged rats have thicker skulls and tougher connective tissue than younger rats and mice, which can delay brain extraction and/or dissection and consequently negate or exaggerate real age-differences in synaptic function and plasticity. Aging and amyloid pathology may also exacerbate hippocampal damage sustained during the dissection procedure, again complicating any inferences drawn from physiologic assessment. Here, we discuss the steps taken during the dissection procedure to minimize these problems.
Examples of synaptic responses acquired in "healthy" and "unhealthy" slices from rats and mice are provided, as well as representative synaptic plasticity experiments. The possible impact of other methodological factors on synaptic function in these animal models (e.g. recording solution components, stimulation parameters) are also discussed. While the focus of this article is on the use of aged rats and transgenic mice, novices to slice physiology should find enough detail here to get started on their own studies, using a variety of rodent models.
See the educational video and download the full article as pdf
Knife Angle in Microtomy
12 January 2011
Tips & Tricks in Sample Preparation
Charles W. Scouten, Ph.D., Leica Microsystems
To prepare biological tissue for observation under a microscope, the tissue is usually cut in thin slices. Most biological tissue is too soft to cut; the knife would push into it and compress it, even if the cutting edge was very sharp.
Therefore, the tissue is either frozen and sectioned in a cryostat or embedded in a hardening material like paraffin or resin, or cut while still soft with a vibrating blade microtome. The correct knife angle is the subject of much misunderstanding, misleading experience, and incorrect information passed between microtomists, but in fact can be logically derived.
Click on the hyperlink above to read the entire article.
Precision-Cut Slices of Normal and Tumorous Liver Tissues
09 December 2009
Generated with the Leica VT1200 S Vibrating Blade Microtome
Abstract
Precision-cut liver tissue slices are a powerful tool to perform studies on pharmacological metabolism as well as studies investigating toxicology and efficacy of novel substances on primary material under standardized conditions. Slicing of primary liver tissue has been realized using different slicing machines. Since there has been great variability in the results, we sought to develop a highly reproducible method for slicing of liver tissue.
Liver samples from five different species (human, mouse, rat, pig, cattle) were cut using the Leica VT1200 S with Vibrocheck and the reproducibility of slice thickness and quality was determined. Compared to slicers used in the field so far, we demonstrated an improved accuracy and reproducibility of tissue slices.
The localization of Nerve Cell Antigens in rat brain with the Leica VT1000 vibrating blade microtome
27 May 2009
Immunohistochemistry is an important research method to study the central nervous system (CNS). During the last three decades, different immunodetection systems have been developed.
CNS antigens can be detected by isotopic, enzymatic and fluorescence systems. Although these methods can be used on brain sections obtained with a cryostat, more accurate localization and superior morphological detail requires the use of non-frozen tissue.
Read the complete applications brief by downloading the pdf via the hyperlink.