Catalog Leica CM1850
Basic instruments
| Code | Name Show all details | Qty |
|---|---|---|
| 14047131148 | Leica CM1850 120 V/60 Hz
Leica CM1850 - Cryostat for Clinical Applications
Leica CM1850 Basic Instrument - 120 V/60 Hz with Peltier cooling System, without specimen retraction Instrument features: Freestanding cryostat on rollers with front- encapsulated microtome. Heated, removable sliding window. Spacious cryochamber with illumination. Removable storage shelves. Corrosion-proof cryochamber for easy decon- tamination. Handwheel lock. Control panel with foil-protected buttons and locking function. Self-explanatory symbols for all essential functions and displays. Microtome: Low-maintenance microtome with cross roller guides. Single-screw locking system for direct fitting of specimen discs. Precision X/Y/Z 8° specimen orientation. Section thickness continuously adjustable from 1 to 60 µm. Total vertical stroke: approx. 60 mm Total horizontal specimen feed: approx. 25 mm Motorized coarse feed at two speed settings (0.2 mm/s; 0.7 mm/s) Visual indication of specimen stop positions (front/home). Cryochamber: Cryochamber temperature setting between 0 and -35 °C. Power saving insulating system. LED display indicates cryochamber temperature, real time and defrost time and Peltier cooling being activated. Manual defrosting function for cryochamber and freezing shelf with sound signal to avoid un- intentional defrosting; defrost cycle duration of 9 minutes. Overheating protection system. Automatic hot-gas defrosting. Starting time programmable in 15-minute increments (cryo- chamber only). Duration of defrost cycle re- gulated by actual cryochamber temperature. Actively cooled freezing shelf -43 °C ( 3 K/-2 K) for 10 specimen discs. Manual hot-gas defrosting of freezing shelf, time-controlled. Peltier cooling system for fast specimen freezing - maximum. Peltier cooling temperature of -55°C; Peltier system automatically switches off after 10 minutes. Collecting tank for condensation water. Section thickness selectable from 1 to 60 µm; adjustable in: 0-10 µm in 1 µm increments 10-20 µm in 2 µm increments 20-60 µm in 5 µm increments Maximum specimen size: 55 mm diameter/2.17 inches Total horizontal specimen feed: approx. 25 mm/0.98 inches Total vertical stroke: approx. 60 mm/2.36 inches Technical Data:
All specifications related to temperature are valid for a room temperature of up to 22°C and a relative air humidity of 60 %. Note: A non-orienting fixture for specimen clamps ('non-orienting specimen head') is also available for the Leica CM1850. Please refer to 'Accessories' for ordering information! Standard delivery with Peltier cooling system includes: 1 Basic instrument (14 0471 31148) 1 Handwheel with marking, antibacterial(14 0471 42558) 1 Heat extractor, stationary, (14 0471 30792) 1 Low temperature stabilizer for heat extractor, ("Parking station") (14 0471 30793) 1 Fixture for specimen clamp, orienting (14 0471 30936) (mounted to the instrument) 1 Knurled nut (14 0471 38471) (included in fixture for specimen clamp, orienting) 1 Set of specimen discs (14 0470 43550):
|
|
| 14047131150 | Leica CM1850 220 V/60 Hz
Leica CM1850 - Cryostat for Clinical Applications
Leica CM1850 Basic Instrument - 220 V/60 Hz with Peltier cooling system, with specimen retraction Instrument features: Freestanding cryostat on rollers with front- encapsulated microtome. Heated, removable sliding window. Spacious cryochamber with illumination. Removable storage shelves. Corrosion-proof cryochamber for easy decon- tamination. Handwheel lock. Control panel with foil-protected buttons and locking function. Self-explanatory symbols for all essential functions and displays. Microtome: Low-maintenance microtome with cross roller guides. Single-screw locking system for direct fitting of specimen discs. Precision X/Y/Z 8° specimen orientation. Section thickness continuously adjustable from 1 to 60 µm. Specimen retraction approx. 180 µm. Total vertical stroke: approx. 60 mm Total horizontal specimen feed: approx. 25 mm Motorized coarse feed at two speed settings (0.2 mm/s; 0.7 mm/s) Visual indication of specimen stop positions (front/home). Cryochamber: Cryochamber temperature setting between 0 and -35 °C. Power saving insulating system. LED display indicates cryochamber temperature, real time and defrost time and Peltier cooling being activated. Manual defrosting function for cryochamber and freezing shelf with sound signal to avoid unintentional defrosting; defrost cycle duration of 9 minutes. Overheating protection system. Automatic hot-gas defrosting. Starting time rogrammable in 15-minute increments (cryo- chamber only). Duration of defrost cycle re- gulated by actual cryochamber temperature. Actively cooled freezing shelf -43 °C ( 3 K/-2 K) for 10 specimen discs. Manual hot-gas defrosting of freezing shelf, time-controlled. Peltier cooling system for fast specimen freezing - maximum Peltier cooling temperature of -55°C; Peltier system auto- matically switches off after 10 minutes. Collecting tank for condensation water. Section thickness selectable from 1 to 60 µm; adjustable in: 0-10 µm in 1 µm increments 10-20 µm in 2 µm increments 20-60 µm in 5 µm increments Maximum specimen size: 55 mm diameter/2.17 inches Total horizontal specimen feed: approx. 25 mm/0.98 inches Total vertical stroke: approx. 60 mm/2.36 inches Technical Data:
All specifications related to temperature are valid for a room temperature of up to 22°C and a relative air humidity of 60 %. Note: A non-orienting fixture for specimen clamps ('non-orienting specimen head') is also available for the Leica CM1850. Please refer to 'Accessories' for ordering information! Standard delivery with Peltier cooling system includes: 1 Basic instrument (14 0471 31150) 1 Handwheel with marking, antibacterial(14 0471 42558) 1 Heat extractor, stationary, (14 0471 30792) 1 Low temperature stabilizer for heat extractor, ("Parking station") (14 0471 30793) 1 Fixture for specimen clamp, orienting (14 0471 30936) (mounted to the instrument) 1 Knurled nut (14 0471 38471) (included in fixture for specimen clamp, orienting) 1 Set of specimen discs (14 0470 43550):
|
|
| 14047131154 | Leica CM1850 230 V/50 Hz
Leica CM1850 - Cryostat for Clinical Applications
Leica CM1850 Basic Instrument - 230 V/50 Hz with Peltier cooling system, with specimen retraction Instrument features: Freestanding cryostat on rollers with front- encapsulated microtome. Heated, removable sliding window. Spacious cryochamber with illumination. Removable storage shelves. Corrosion-proof cryochamber for easy decon- tamination. Handwheel lock. Control panel with foil-protected buttons and locking function. Self-explanatory symbols for all essential functions and displays. Microtome: Low-maintenance microtome with cross roller guides. Single-screw locking system for direct fit- ting of specimen discs. Precision X/Y/Z 8° specimen orientation. Section thickness continuously adjustable from 1 to 60 µm. Specimen retraction approx. 180 µm Total vertical stroke: approx. 60 mm Total horizontal specimen feed: approx. 25 mm Motorized coarse feed at two speed settings (0.2 mm/s; 0.7 mm/s) Visual indication of specimen stop positions (front/home). Cryochamber: Cryochamber temperature setting between 0 and -35 °C. Power saving insulating system. LED display indicates cryochamber temperature, real time and defrost time and Peltier cooling being activated. Manual defrosting function for cryochamber and freezing shelf with sound signal to avoid un- intentional defrosting; defrost cycle duration duration of 9 minutes. Overheating protection system. Automatic hot-gas defrosting. Starting time programmable in 15-minute increments (cryo- chamber only). Duration of defrost cycle re- gulated by actual cryochamber temperature. Actively cooled freezing shelf -43 °C ( 3 K/-2 K) for 10 specimen discs. Manual hot-gas defrosting of freezing shelf, time-controlled. Peltier cooling system for fast specimen freezing - maximum Peltier cooling temperature of -55°C; Peltier system automatically switches off after 10 minutes. Collecting tank for condensation water. Section thickness selectable from 1 to 60 µm; adjustable in: 0-10 µm in 1 µm increments 10-20 µm in 2 µm increments 20-60 µm in 5 µm increments Maximum specimen size: 55 mm diameter/2.17 inches Total horizontal specimen feed: approx. 25 mm/0.98 inches Total vertical stroke: approx. 60 mm/2.36 inches Technical Data:
All specifications related to temperature are valid for a room temperature of up to 22°C and a relative air humidity of 60 %. Note: A non-orienting fixture for specimen clamps ('non-orienting specimen head') is also available for the Leica CM1850. Please refer to 'Accessories' for ordering information! Standard delivery with Peltier cooling system includes: 1 Basic instrument (14 0471 31154) 1 Handwheel with marking, antibacterial(14 0471 42558) 1 Heat extractor, stationary, (14 0471 30792) 1 Low temperature stabilizer for heat extractor, ("Parking station") (14 0471 30793) 1 Fixture for specimen clamp, orienting (14 0471 30936) (mounted to the instrument) 1 Knurled nut (14 0471 38471) (included in fixture for specimen clamp, orienting) 1 Set of specimen discs (14 0470 43550):
|
|
| 14047131152 | Leica CM1850 240 V/50 Hz
Leica CM1850 - Cryostat for Clinical Applications
Leica CM1850 Basic Instrument - 240 V/50 Hz with Peltier cooling system, with specimen retraction Instrument features: Freestanding cryostat on rollers with front- encapsulated microtome. Heated, removable sliding window. Spacious cryo- chamber with illumination. Removable storage shelves. Corrosion-proof cryochamber for easy decon- tamination. Handwheel lock. Control panel with foil-protected buttons and locking function. Self exlanatory symbols for all essential functions and displays. Microtome: Low-maintenance microtome with cross roller guides. Single-screw locking system for direct fit- ting of specimen discs. Precision X/Y/Z 8° specimen orientation. Section thickness continuously adjustable from 1 to 60 µm. Specimen retraction approx. 180 µm Total vertical stroke: approx. 60 mm Total horizontal specimen feed: approx. 25 mm Motorized coarse feed at two speed settings (0.2 mm/s; 0.7 mm/s) Visual indication of specimen stop positions (front/home). Cryochamber: Cryochamber temperature setting between 0 and -35°C. Power saving insulating system. LED display indicates cryochamber temperature, real time and defrost time and Peltier cooling being activated. Manual defrosting function for cryochamber and freezing shelf with sound signal to avoid un- indentional defrosting. Defrost cycle duration of 9 minutes. Overheating protection system. Automatic hot-gas defrosting. Starting time programmable in 15-minute increments (cryo- chamber only). Duration of defrost cycle re- gulated by actual cryochamber temperature. Actively cooled freezing shelf -43°C ( 3 K/-2 K) for 10 specimen discs. Manual hot-gas defrosting of freezing shelf, time-controlled. Peltier cooling system for fast specimen freezing - maximum Peltier cooling temperature of -55°C; Peltier system auto- matically switches off after 10 minutes. Collecting tank for condensation water. Section thickness selectable from 1 to 60 µm; adjustable in: 0-10 µm in 1 µm increments 10-20 µm in 2 µm increments 20-60 µm in 5 µm increments Maximum specimen size: 55 mm diameter/2.17 inches Total horizontal specimen feed: approx. 25 mm/0.98 inches Total vertical stroke: approx. 60 mm/2.36 inches Technical Data:
All specifications related to temperature are valid for a room temperature of up to 22°C and a air humidity of 60 %. Note: A non-orienting fixture for specimen clamps ('non-orienting specimen head') is also available for the Leica CM1850. Please refer to 'Accessories' for ordering information! Standard delivery with Peltier cooling system includes: 1 Basic instrument (14 0471 31148) 1 Handwheel with marking, antibacterial(14 0471 42558) 1 Heat extractor, stationary, (14 0471 30792) 1 Low temperature stabilizer for heat extractor, ("Parking station") (14 0471 30793) 1 Fixture for specimen clamp, orienting (14 0471 30936) (mounted to the instrument) 1 Knurled nut (14 0471 38471) (included in fixture for specimen clamp, orienting) 1 Set of specimen discs (14 0470 43550):
NOTE: This instrument is supplied with Australian power cord (orange color) fitted with standard Australian mains plug (transparent color). |
|
Configurations
| Code | Name Show all details | Qty |
|---|---|---|
| 14901850001 | Leica CM1850 configured
Leica CM1850 - Configuration 1:
Leica CM1850 Configuration - 120 V/60 Hz with Peltier cooling without specimen retraction knife holder CE for low profile disposable blades Instrument features: Freestanding cryostat on rollers with front- encapsulated microtome. Heated, removable sliding window. Spacious cryochamber with illumination. Removable storage shelves. Corrosion-proof cryochamber for easy decon- tamination. Handwheel lock. Control panel with foil-protected buttons and locking function. Self-explanatory symbols for all essential functions and displays. Microtome: Low-maintenance microtome with cross roller guides. Single-screw locking system for direct fit- ting of specimen discs. Precision X/Y/Z 8° specimen orientation. Section thickness continuously adjustable from 1 to 60 µm. Total vertical stroke: approx. 60 mm Total horizontal specimen feed: approx.25 mm Motorized coarse feed at two speed settings (0.2 mm/s; 0.7 mm/s) Visual indication of specimen stop positions (front/home). Cryochamber: Cryochamber temperature setting between 0 and -35 °C. Power saving insulating system. LED display indicates cryochamber temperature, real time, defrost time and activation of Peltier cooling. Manual defrosting function for chamber and freezing shelf with sound signal to avoid unintentional defrosting; defrost cycle duration of 9 minutes. Overheating protection system. Automatic hot-gas defrosting, programmable in 15-minute increments (cryochamber only). Duration of defrost cycle regulated by actual cryochamber temperature. Actively cooled freezing shelf -43 °C ( 3 K/-2 K) for 10 specimen discs. Manual hot-gas defrosting of freezing shelf, time-controlled. Peltier cooling system for fast specimen freezing - maximum Peltier cooling temperature of -55 °C; Peltier system auto- matically switches off after 10 minutes. Collecting tank for condensation water. Technical Data:
All specifications related to temperature are valid for a room temperature of up to 22° C and a relative air humidity of 60 %. Note: This configuration comes with knife holder base and knife holder CE for high and low profile disposable blades. Standard delivery with Peltier cooling system includes: 1 Basic instrument (14 0471 31148) 1 Handwheel with marking, antibacterial(14 0471 42558) 1 Heat extractor, stationary, (14 0471 30792) 1 Low temperature stabilizer for heat extractor, ("Parking station") (14 0471 30793) 1 Fixture for specimen clamp, orienting (14 0471 30936) (mounted to the instrument) 1 Knurled nut (14 0471 38471) (included in fixture for specimen clamp, orienting) 1 Set of specimen discs (14 0470 43550):
|
|
| 1491850CE01 | Leica CM1850 configured
Leica CM1850 - Configuration 2:
Leica CM1850 Configuration - 230 V/50 Hz with Peltier cooling and specimen retraction knife holder CE for low profile disposable blades Instrument features: Freestanding cryostat on rollers with front- encapsulated microtome. Heated, removable sliding window. Spacious cryochamber with illumination. Removable storage shelves. Corrosion-proof cryochamber for easy decon- tamination. Handwheel lock. Control panel with foil-protected buttons and locking function. Self-explanatory symbols for all essential functions and displays. Microtome: Low-maintenance microtome with cross roller guides. Single-screw locking system for direct fit- ting of specimen discs. Precision X/Y/Z 8° specimen orientation. Section thickness continuously adjustable from 1 to 60 µm. Specimen retraction: approx. 180 µm Total vertical stroke: approx. 60 mm Total horizontal specimen feed: approx. 25 mm Motorized coarse feed at two speed settings (0.2 mm/s; 0.7 mm/s) Visual indication of specimen stop positions (front/home). Cryochamber: Cryochamber temperature setting between 0 and -35 °C. Power saving insulating system. LED display indicates cryochamber temperature, real time, defrost time and activation of Peltier cooling. Manual defrosting function for chamber and freezing shelf with sound signal to avoid unintentional defrosting; defrost cycle duration of 9 minutes. Overheating protection system. Automatic hot-gas defrosting, programmable in 15-minute increments (cryochamber only). Duration of defrost cycle regulated by actual cryochamber temperature. Actively cooled freezing shelf -43 °C ( 3 K/-2 K) for 10 specimen discs. Manual hot-gas defrosting of freezing shelf, time-controlled. Peltier cooling system for fast specimen freezing - maximum Peltier cooling temperature of -55 °C; Peltier system automatically switches off after 10 minutes. Collecting tank for condensation water. Technical Data:
All specifications related to temperature are valid for a room temperature of up to 22 °C and a relative air humidity of 60 %. Note: This configuration comes with knife holder CE for high and low profile disposable blades. Standard delivery with Peltier cooling system and CE-Holder: 1 Basic instrument, 230V/50Hz, with Peltier (0471 31154) 1 Handwheel with marking, antibacterial(14 0471 42558) 1 Heat extractor, stationary, (14 0471 30792) 1 Low temperature stabilizer for heat extractor, ("Parking station") (14 0471 30793) 1 Fixture for specimen clamp, orienting (14 0471 30936) (mounted to the instrument) 1 Knurled nut (14 0471 38471) (included in fixture for specimen clamp, orienting) 1 Set of specimen discs (14 0470 43550):
|
|
Knife holders and Knife holder base
| Code | Name Show all details | Qty |
|---|---|---|
| 14080037740 | Anti-static kit high-pr.
Anti-static kit for knife holder CE
for high profile disposable blades ![]() |
|
| 14080037739 | Anti-static kit low-prof.
Anti-static kit for knife holder CE
for low profile disposable blades ![]() |
|
| 14041926140 | Knife holder base for CN, CE, CS
Knife holder base for CN and CE holder
|
|
| 14041933993 | Knife holder CN w/o knife holder base
Knife holder CN:
Knife holder CN for reusable microtome knives or magnetic blade rails. Clearance angle setting and knife height adjustment. Knife support rails for short and long knives. Anti-roll guide and adjustable knife guard. ![]() |
|
| 14041933990 | Knife holder CE low prof.
Knife holder CE:
Knife holder CE for low profile disposable blades with lateral displacement feature and glass anti-roll guide. Clearance angle setting. ![]() |
|
| 14041933991 | Knife holder CE high prof.
Knife holder CE:
Knife holder CE for high profile disposable blades, with lateral displacement feature and glass anti-roll guide. Clearance angle setting. |
|
| 14041933992 | Knife holder CE
Knife holder CE:
Knife holder CE for low profile disposable blades, w/o clearance angle adjustment, including knife holder base and pressure plates. ![]() |
|
| 14041932073 | Knife holder CE-TC
Knife holder CE-TC for Tungsten Carbide
disposable blades. Especially suitable for sectioning harder specimens, such as tissue with bone or cartilage. |
|
| 14041935693 | Anti-roll guide, assy. 70mm, tilting
Retrofit kit:
tilting device with anti-roll system CE Consisting off: tilting device anti-roll system CE:
(14 0419 33990, 14 0419 33991, 14 0419 33992) ![]() |
|
| 14041933980 | Anti-roll plate, assy. 70mm 100µm
Anti-roll system CE, glass - 70 mm
For standard application Consisting off:
(14 0419 33990, 14 0419 33991, 14 0419 33992) ![]() |
|
| 14041933981 | Anti-roll plate,assy. glass 50mm
Anti-roll system for knife holder CN or knife holder CNZ,
consisting of:
![]() |
|
| 14041937258 | Anti-roll plate, assy. 70mm 50µm
Anti-roll system CE, glass - 70 mm
For special application Consisting off:
(14 0419 33990, 14 0419 33991, 14 0419 33992) |
|
| 14041937260 | Anti-roll plate, assy. 70mm 150µm
Anti-roll system CE, glass - 70 mm
For special application Consisting off:
(14 0419 33990, 14 0419 33991, 14 0419 33992) |
|
| 14047742497 | Glass insert 70 mm pol.
Glare-minimizing glass insert, 70 mm wide;
replacement glass for anti-roll systems CE (14 0477 42491, 14 0477 42492, 14 0477 42493) for blade holder CE (14 0477 43005) ![]() |
|
| 14041933816 | Anti-roll plate, glass 50mm
Glass insert - 50 mm
For knife holder CN (14 0477 42358) |
|
| 14050229553 | Pressure plate rear HP, 22°
Pressure plate B, 22 °, for high profile blades
|
|
| 14050229551 | Pressure plate rear LP, 22°
Pressure plate S, 22 °, for low profile blades
|
|
| 14041919426 | Knife support
Knife support bar for knife holder CN
for short knives |
|
| 14041919427 | Knife support
Knife support bar for knife holder CN
for long knives |
|
Disposable knives
| Code | Name Show all details | Qty |
|---|---|---|
| 14021626379 | Disposable blades TC-65
Leica TC65 Microtome Blade System for hard
Material sectioning The Leica TC65 tungsten carbide disposable blades are specially designed and manu- factured to meet the stringent require- ements of laboratories routinely sec- tioning hard and abrasive materials. The unique cutting edge treatment guarantees sections down to approx.1µm. The blades are fully recyclable. length: 65 mm thickness: 1 mm height: 11 mm Leica TC65 tungsten carbide disposable blades. Box of 5. |
|
| 14035838926 | High-profile disposable blades818 (1x50)
Leica Disposable Blades, high profile (818)
80 mm long, 14 mm high 1 Package of 50 blades ![]() |
|
| 14035838383 | High-profile disposable blades818(10x50)
Leica Disposable Blades, high profile (818)
80 mm long, 14 mm high 10 Packages of 50 blades each ![]() |
|
| 14035838925 | Low-profile disposable blades 819 (1x50)
Leica Disposable Blades, low profile (819)
80 mm long, 8 mm high 1 Package of 50 blades ![]() |
|
| 14035838382 | Low-profile disposable blades 819(10x50)
Leica Disposable Blades, low profile (819)
80 mm long, 8 mm high 10 Packages of 50 blades each ![]() |
|
Reusable knives
| Code | Name Show all details | Qty |
|---|---|---|
| 14021607100 | Knife 16cm - profile c - steel
Knife, 16 cm long, profile c (plane on both
sides, for paraffin and frozen sections ) Note: Knife case 14 0213 11140 included ![]() |
|
| 14021604206 | Knife 16 cm c TC
Knife, 16 cm TC edge, profile c
Note: Knife case 14 0213 11140 included ![]() |
|
| 14021607092 | Knife 12 cm c steel
Knife, 12 cm long, profile c
Note: Knife case 14 0213 11140 included ![]() |
|
| 14021607132 | Knife 16cm - profile d - steel
Knife, 16 cm long, profile d
Note: Knife case 14 0213 11140 included ![]() |
|
| 14021604813 | Knife 16 cm d TC
Knife, 16 cm TC- edge, profile d
Note: Knife case 14 0213 11140 included |
|
| 14021607130 | Knife 12 cm d steel
Knife, 12 cm long, profile d
Note: Knife case 14 0213 11140 included ![]() |
|
| 14021311140 | Knife case
Variable plastic knife case for 1 or 2 knives
from 10 up to 16 cm length ![]() |
|
| 14021311141 | Knife case
Variable plastic knife case for 1 or 2 knives,
18.5, 22 or 30 cm long (tungsten carbide or SM 2500 knives: for 1 knife only!) ![]() |
|
Dr.Peters Cryoembedding systems
| Code | Name Show all details | Qty |
|---|---|---|
| 14020140670 | Case w/embedding systems
Case with cryoembedding system includes:
![]() |
|
| 14020139115 | Cryoembed.system cpl.set
Cryoembedding System, complete set
consisting of:
![]() |
|
| 14020139116 | Embed. well bar set 18 mm
Small Embedding Well Bar Set
consisting of:
![]() |
|
| 14020139117 | Embed. well bar set 24 mm
Medium Embedding Well Bar Set
consisting of:
![]() |
|
| 14020139118 | Embed. well bar set 30 mm
Large Embedding Well Bar Set
consisting of:
![]() |
|
| 14020139119 | Freez.griddle/block elev.
Freezing Griddle / elevated heat extractor
consisting of:
![]() |
|
| 14020139120 | Embedding well bar 4x18mm
Embedding Well Bar
thickness: 1 inch size: 4 x 18 mm stainless steel 4 wells ![]() |
|
| 14020139121 | Embedding well bar 4x24mm
Embedding Well Bar
thickness: 1 inch size: 4 x 24 mm stainless steel 4 wells ![]() |
|
| 14020139122 | Embedding well bar 3x30mm
Embedding Well Bar
thickness: 1 inch size: 3 x 30 mm stainless steel 3 wells ![]() |
|
| 14020146662 | Embedding well bar, small
Embedding well bar, small
for use with Dr. Peter´s cryoembedding system with 4 wells Two wells: LxWxH: 20 x 20 x 6 mm Two wells: LxWxH: 20 x 20 x 9 mm |
|
| 14020146663 | Embedding well bar, large
Embedding well bar, large
for use with Dr. Peter´s cryoembedding system; with 4 wells Two wells: LxWxH: 24 x 24 x 6 mm Two wells: LxWxH: 24 x 24 x 9 mm |
|
| 14020139123 | Spec. stage square 28 mm
Specimen stage, square
stainless steel small - 28 mm pack of 1 ![]() |
|
| 14020139124 | Spec. stage square 36 mm
Specimen stage, square
stainless steel large - 36 mm pack of 1 ![]() |
|
| 14020139125 | Ovewr-disc heat extractor
Over-stage heat extractor
![]() |
|
| 14020139126 | Bin for discs
Bin for stages
![]() |
|
| 14020139127 | Dispensing slides 8 pcs.
Dispensing slides for Dr. Peter´s
cryoembedding system pack of 8 ![]() |
|
Accessories
| Code | Name Show all details | Qty |
|---|---|---|
| 14047743247 | O-ring blue (10pcs)
O-ring blue, for color-marking of 20 mm
and 30 mm diameter sepecimen disc (14 0477 40044) pack of 10 ![]() |
|
| 14047743248 | O-ring red (10pcs)
O-ring red, for color-marking of 20 mm
and 30 mm diameter specimen disc (14 0477 40044) pack of 10 ![]() |
|
| 14047743249 | O-ring blue (10pcs)
O-ring blue, for color-marking of 40 mm diameter
specimen disc (14 0477 40045) pack of 10 ![]() |
|
| 14047743250 | O-ring red (10pcs)
O-ring red, for color-marking of 40 mm diameter
specimen disc (14 0477 40045) pack of 10 ![]() |
|
| 14047743251 | O-ring blue (10pcs)
O-ring blue, for color-marking of 55 mm diameter
specimen disc (14 0477 40046) pack of 10 ![]() |
|
| 14047743252 | O-ring red (10pcs)
O-ring red, for color-marking of 55 mm diameter
specimen disc (14 0477 40046) pack of 10 ![]() |
|
| 14043643463 | Tool kit CM..
Tool kit for Cryostats, consisting of:
![]() |
|
| 14071240150 | Easy Dip staining cnt. wt
Easy Dip, Slide Staining Vessel
white pack of 6 ![]() |
|
| 14071240151 | Easy Dip staining cnt. pk
Easy Dip, Slide Stainig Vessel
pink pack of 6 ![]() |
|
| 14071240152 | Easy Dip staining cnt.grn
Easy Dip, Slide Staining Vessel
green pack of 6 ![]() |
|
| 14071240153 | Easy Dip staining cnt. yl
Easy Dip, Slide Staining Vessel
yellow pack of 6 ![]() |
|
| 14071240154 | Easy Dip staining cnt. bl
Easy Dip, Slide Staining Vessel
blue pack of 6 ![]() |
|
| 14071240161 | Easy Dip Stain. rack grey
Easy Dip, Slide Staining Rack
for 12 microscope slides gray pack of 6 ![]() |
|
| 14037008636 | Specimen disc, 20mm
Specimen disc 20 mm
|
|
| 14041619275 | Specimen disc, 25mm
Specimen disc 25 mm
|
|
| 14037008587 | Specimen disc, 30mm
Specimen disc 30 mm
|
|
| 14037008637 | Specimen disc, 40mm
Specimen disc 40 mm
|
|
| 14041926491 | Specimen disc, 55mm
Specimen disc 55 mm
|
|
| 14041926750 | Specimen stage
Specimen disc 50 x 80 mm
|
|
| 14044326836 | Heat extractor
Heat extractor - mobile
|
|
| 14041638207 | Transfer block
Transfer block for specimen discs
(LxWxH): 190 x 75 x 25 mm ![]() |
|
| 14039818542 | Thermal block
Thermal block for removal of frozen specimens
from specimen disc |
|
| 14043626747 | Miles adapter
Adapter for Miles TissueTek® specimen discs
|
|
| 14041145349 | Plug adapter set EU-UK
Plug adapter set EU-UK,
for use with EG1120, EG1130, CM1100, CM1510 S,CM1850 UV, CM3050 S, SP1600 220/230 V/50 Hz versions only. |
|
Consumables
| Code | Name Show all details | Qty |
|---|---|---|
| 14041935693 | Anti-roll guide, assy. 70mm, tilting
Retrofit kit:
tilting device with anti-roll system CE Consisting off: tilting device anti-roll system CE:
(14 0419 33990, 14 0419 33991, 14 0419 33992) ![]() |
|
| 14041933980 | Anti-roll plate, assy. 70mm 100µm
Anti-roll system CE, glass - 70 mm
For standard application Consisting off:
(14 0419 33990, 14 0419 33991, 14 0419 33992) ![]() |
|
| 14041933981 | Anti-roll plate,assy. glass 50mm
Anti-roll system for knife holder CN or knife holder CNZ,
consisting of:
![]() |
|
| 14041937258 | Anti-roll plate, assy. 70mm 50µm
Anti-roll system CE, glass - 70 mm
For special application Consisting off:
(14 0419 33990, 14 0419 33991, 14 0419 33992) |
|
| 14041937260 | Anti-roll plate, assy. 70mm 150µm
Anti-roll system CE, glass - 70 mm
For special application Consisting off:
(14 0419 33990, 14 0419 33991, 14 0419 33992) |
|
| 14047742497 | Glass insert 70 mm pol.
Glare-minimizing glass insert, 70 mm wide;
replacement glass for anti-roll systems CE (14 0477 42491, 14 0477 42492, 14 0477 42493) for blade holder CE (14 0477 43005) ![]() |
|
| 14041933816 | Anti-roll plate, glass 50mm
Glass insert - 50 mm
For knife holder CN (14 0477 42358) |
|
| 14020108926 | Tissue freezing medium, 125 ml
Tissue freezing medium for cryosectioning
125 ml |
|
| 14033606100 | Cryo-oil type 407, 250 ml
Cryostat oil - type 407, bottle of 250 ml
Shelf life 36 months |
|
| 14038742801 | [H] Leica Cryofect 4 x 350 ml
Caution: Dangerous goods
Leica Cryofect - Low temperature disinfectant, 4 bottles of 350 ml each. For temperatures down to -20°C ![]() |
|
| 14034040859 | Safety gloves size S
Cut resistant safety gloves
size S |
|
| 14034029011 | Safety gloves size M
Cut resistant safety gloves
size M |
|
Accessories for Manual Knives sharpening
| Code | Name Show all details | Qty |
|---|---|---|
| 14033708686 | Strop.back kn.22 cm b&c
Stropping back for knives profile c, 22 cm long
|
|
| 14033708687 | Strop.back kn.16 cm b&c
Stropping back for knives profile c, 16 cm long
|
|
| 14033708688 | Strop.back kn.12 cm b&c
Stropping back for knives profile c, 12 cm long
|
|
| 14033708689 | Strop.back kn.10 cm b&c
Stropping back for knives profile c, 10 cm long
|
|
| 14033708691 | Strop.back kn.25 cm d
Stropping back for knives profile d, 25 cm long
|
|
| 14033708692 | Strop.back kn.22 cm d
Stropping back for knives profile d, 22 cm long
|
|
| 14033708693 | Strop.back kn.16 cm b&c
Stropping back for knives profile d, 16 cm long
|
|
| 14028308504 | Handle f. knives 10-30 cm
Handle for knives from 10 to 30 cm long
|
|
| 14021004070 | Hon.stone fine yl 25x5.5
Honing stone (fine),
yellow with dark back, approx. 25 x 5.5 cm |
|
| 14021004071 | Hon.stone bl-gr 25x5.5 cm
Honing stone (coarse),
blue green, with scraper, approx. 25 x 5.5 cm |
|
| 14021004073 | Metal case f. hon.stones
Metal case for honing stones
Cat. No. 0337 04070 or 0337 04071 |
|
| 14020904066 | Strop block 'Heidelberg'
Strop block, "Heidelberg type"
|
|
| 14028507057 | Clamp f.strop block HD
Table clamp for strop block, "Heidelberg type"
|
|
| 14020904064 | Strop paste, red
Strop paste, red
|
|
Accessories for Leica Cryoclean
| Code | Name Show all details | Qty |
|---|---|---|
| 14047334541 | Bactericidal filter
Bactericidal filters - to filer out bacteria
from exhaust air; pack of 5 |
|
| 14047331455 | Filter bags for Cryoclean
Filter bags for Cryoclean - for section waste
collection; pack of 5 |
|