DIC Microscopes

Most people use brightfield illumination when using a microscope. Unfortunately, it usually provides just a low-contrast image of many biological specimens where few details can be distinguished. Selective stains can be used to enhance the contrast with brightfield, but there is the risk that the stains can be toxic to living cells. With DIC microscopy, where DIC means differential interference contrast, no stains are needed to see the structures of many types of biological specimens with greater contrast compared to brightfield. The contrast method exploits polarized light and differences in thickness or optical density of the specimen that lead to a phase shift of the light passing through it.

DIC is offered with specific Leica microscopes. It can be useful for the observation of cells or tissues in a variety of life-science or forensic applications. DIC microscopy can also be helpful for certain material and mineral applications.

Need Assistance?

Contact us for expert advice on the right dic microscope for your needs and budget.

Card Icon

What is DIC microscopy and what is it used for?

DIC is differential interference contrast, an optical contrast technique for microscopy which allows unstained structures in the cells of biological specimens to be observed with adequate contrast and resolution. It can also help to visualize small height differences on the surfaces of materials. Only polarized light is used to illuminate the specimen. The polarized light is dispersed into two distinct light rays with an orthogonal plane of polarization. As the rays experience different refraction or scattering in the specimen, different phase shifts occur. When these light rays reunite, they interfere and become elliptically polarized. This polarization can be changed into an amplitude shift via an analyzer. Phase shifts corresponding to differences as small as 1/1000 of a wavelength (when detected with a camera sensor) can be observed in the DIC images. DIC microscopy images are relief-like and seem to have a shadow.

Card Icon

How do you set up DIC microscopy?

DIC microscope is a widefield microscopy which has a polarization filter and Wollaston prism between the light source and condenser lens and also between the objective lens and camera sensor or eyepieces. For more information about how it is set up, refer to the articles: Differential Interference Contrast (DIC)Metallography

How does differential interference contrast (DIC) microscopy work?

DIC microscope is a conventional widefield microscope which uses polarization filters and Wollaston prisms.

Light from a source passes through a filter and becomes 45° polarized. After passing through a Wollaston prism, the light is separated into perpendicular polarized components where one is 0° and the other 90° polarized. The condenser lens focusses the light onto the specimen which is illuminated by 2 coherent parallel rays with different polarization. The rays experience different optical path lengths, as there may be differences in thickness or refractive index along the path where they pass through the specimen.

The result is a phase shift of one ray compared to the other. After passing through the objective and another Wollaston prism, the perpendicularly polarized light is recombined to become one which is 135° polarized. Depending on the differences in the optical path lengths, interference of the 2 rays results in constructive (brightening) or destructive (darkening) interference, making what were hardly visible structures with brightfield now observable with DIC.

Finally, directly transmitted light, which did not experience any phase shift, is removed by the polarization filter (also called analyzer) which only lets 135°-polarized light pass. For more details, refer to the article: Differential Interference Contrast (DIC)

DIC Microscopes

Filter by Area of Application
THUNDER Imager 3D Cell Culture

THUNDER Imager Live Cell & 3D Cell Culture & 3D Assay

THUNDER Imagers provide you with a solution for advanced 3D cell culture assays, whether you want to study stem cells, spheroids, or organoids.

THUNDER Imager Tissue

The THUNDER Imager Tissue allows real-time fluorescence imaging of 3D tissue sections typically used in neuroscience and histology research.

Leica DM4 B & DM6 B

Increase work efficiency with Leica DM4 B & DM6 B upright digital research microscopes.

The Leica DM1000 LED combines the advantages of a fully ergonomic system microscope with innovative LED illumination, and unlimited possibilities in mobile use.

Leica DM1000 LED

Uniquely ergonomic system microscope with LED illumination

The ergonomically designed Leica DM2000 is ideal for sophisticated clinical applications, and other challenging tasks.

Leica DM2000 & DM2000 LED

Ergonomic System Microscopes for Complex Clinical Applications

Ergonomic microscope system Leica DM2500 LED for demanding tasks in life science applications

Leica DM2500 & DM2500 LED

Ergonomic optical microscope systems for routine and research applications

The uniquely ergonomic system microscope Leica DM3000 boosts cytology and pathology workflows thanks to its intelligent automation.

Leica DM3000 & DM3000 LED

Uniquely Ergonomic System Microscopes With Intelligent Automation

Life Science Research

Leica microscopes providing DIC are used in life science research for the visualization, analysis, and documentation of biological structures and cellular processes.

Read More

Forensics

For forensic applications  concerning the evidentiary investigation of materials and human tissues, Leica microscopes offering DIC are very useful solutions.

Read More

Materials and Earth Science

Leica microscopes capable of DIC make a difference for the study of minerals, metals, and ceramics.

Read More

Frequently Asked Questions DIC Microscopes

A DIC microscope is similar to a conventional brightfield microscope, except it uses a polarization filter and Wollaston prism between the light source and condenser lens and also between the objective and camera sensor or eyepieces. For more information, refer to the articles: Differential Interference Contrast (DIC) & Metallography

In the early 1950s, Georges Nomarski invented the microscopy contrast technique called differential interference contrast or DIC. Today, it is still a widely used technique. For more details, refer to the articles: A Brief History of Light MicroscopyDifferential Interference Contrast (DIC)

Yes, a DIC microscope can be equipped with a camera for recording DIC images observed with the contrast method.

Related Articles

Interested to know more?

Talk to our experts. We are happy to answer all your questions and concerns.

Contact Us

Do you prefer personal consulting?

  • Leica Microsystems Inc.
    1700 Leider Lane
    Buffalo Grove, IL 60089 United States
    Office Phone : +1 800 248 0123
    Service Phone : 1 800 248 0223
    Fax : +1 847-236-3009

You will find a more detailed list of local contacts here.