Contact & Support

Electron Microscope

RSS feed
  • See the Structure with Microscopy - Know the Composition with Laser Spectroscopy

    The advantages of a 2-in-1 materials analysis solution combining optical microscopy and laser induced breakdown spectroscopy (LIBS) for simultaneous visual and chemical inspection are described in this report. The basic principles of the 2-in-1 solution and a comparison between it and other common materials analysis methods, such scanning electron microscopy (SEM), are explained to demonstrate how a rapid, efficient workflow is achieved. A 2-in-1 analysis solution can reduce significantly the cost and time for obtaining material image and composition data. Such data are instrumental in assuring quality and reliability to make confident decisions quickly during production, quality control, failure analysis, and research and development in industries and fields, such as automotive and metallurgy.
    Read article
  • Free Webinar-on-Demand: Mechanical pre-preparation and ion milling for SEM observation

    See how the unique combination of pre-preparation system and ion milling system makes fast site specific sample preparation for Scanning Electron Microscopy or optical microscopy possible.
    Read article
  • Free Webinar On-Demand: Practical Applications of Broad Ion Beam Milling

    Mechanical polishing can be time consuming and frustrating. It can also introduce unwanted artifacts when preparing cross-sectioned samples for electron backscatter diffraction (EBSD) in the scanning electron microscope (SEM) or light microscope investigation. In contrast, ion beam milling can eliminate undesirable artifacts that will hamper your analysis and interpretation.
    Read article
  • Free Webinar On-Demand: Revealing Cellular Dynamics with Millisecond Precision

    What if you can dissect the cellular dynamics with millisecond precision? What if you can unravel the morphological transformation of a neuron millisecond by millisecond using electron microscopy?
    Read article
  • Interview with Dr. Shigeki Watanabe on Research in Synaptic Membrane Dynamics

    Dr. Shigeki Watanabe, principle investigator of the department of Cell Biology at the Johns Hopkins University School of Medicine in Baltimore, held a workshop in Zürich, Switzerland on methods to study synaptic dynamics with millisecond precision. In collaboration with Dr. Andres Käch from the University of Zurich all workshop attendees enjoyed presentations and hands-on sessions on the EM ICE by Leica Microsystems with Light and Electrical Stimulation, revealing the latest developments in brain research. During this workshop Dr. Bernd Sägmüller from Leica Microsystems had the chance for an interview with Dr. Watanabe.
    Read article
  • Micro-CT of Insect Larva Protocol

    Species: red blood worm (midge larva) Critical point drying of midge larvae with subsequent X-ray micro-computed tomography (micro-CT) to reconstruct the inner anatomy.
    Read article
  • Contrast Enhancement of Polycrystalline Metals - Sample Preparation for SEM

    Application Note - Ion milling is a perfect alternative for chemical etching, especially for polycrystalline metals, such as copper. Ion milling can be used to increase the contrast of the grain structure and their interfaces. In contrast to chemical etching the milling process is clean, safe and easy to operate. Ion energy and milling time depend on the milling rate of the metal.
    Read article
  • Cross Sectioning of Cadmiumsulphide (CdS) for Cathodoluminescence

    Cathodoluminescence can be used to achieve spectra and high resolution images of impurity and structural defects in semicondoctors, minerals and insulating materials. This application note explains how to prepare a perfect sample surface for carhodoluminescence and how to use ion beam slope cutting to prepare the sample surface free of any preparation artefacts.
    Read article
  • Picea abies (L.) KARST - Sample Preparation for TEM

    Application Note for Leica EM AMW - Plants (5-years old) were grown in pots filled with soil and kept in greenhouse conditions. Five weeks before harvesting the plants were transferred into growth chambers and cultivated at a temperature of 20°C during daytime and 12°C overnight. The relative humidity was set at 60% and the photoactive radiation was 500 μmol m-2 s-1 during daytime. Sample preparation for transmission electron microscopy (TEM) was performed in order to develop a standard protocol that would reduce sample preparation time for TEM-investigations. Therefore the overall and fine structure of leaf cells prepared with the Leica EM AMW were compared with leaf cells that were prepared with a conventional fixation protocol at room temperature.
    Read article
  • Cross Sectioning of Copper for Electron Backscattered Diffraction (EBSD)

    Application Note for Leica EM TIC 3X - Electron Backscattered Diffraction (EBSD) is a surface technique creating diffraction patterns (Kikuchi-bands). It can be used for crystal orientation mapping, defect studies, phase identification, grain boundary studies and morphological studies. The information depth is just a few nm, therefore good sample preparation is very important to avoid damages.
    Read article
  • Porous Ceramics - Sample Preparation for SEM

    Application Note for Leica EM RES102 - Ceramic membrane filters with pore sizes down to a few nanometres must be investigated in cross-section with regard to the structure of the pores. The smallest pores are of special interest. In most cases, conventional grinding methods cannot be used for such problems, as the pore structure would be distorted. This applies in particular to the pores in the nanometre range.
    Read article
  • Maple (Acer saccharum) Leaves - High Pressure Freezing and Freeze Substitution for TEM

    Application Note for Leica EM HPM100 - Leaves were immersed in hexadecene and placed under a gentle (0.3 bar) vacuum for 10 minutes to evacuate the internal air spaces. The leaves were then trimmed to fit the carriers and placed in the 200 μm side of a 6 mm Type A specimen carrier. Free space was filled with additional hexadecene after which a 6 mm Type B specimen carrier was placed on top with the flat side down.
    Read article
  • Removal of Surface Layers - Sample Preparation for SEM and TEM

    Application Note for Leica EM RES102 - Sometimes it is necessary to remove surface layers to gain access to the real surface structure. That can be a native oxide, or layers coming from the preparation process itself, like re-deposition. Depending on the layers thickness and the energy used for the cleaning process, it takes between a few seconds and half an hour. The energy depends on the milling rate of the material.
    Read article
  • Semiconductor Structures with Large Differences in Hardness - Sample Preparation for SEM

    Application Note for Leica EM RES102 - In most cases, multi-layer structures or material combinations with large differences in hardness cannot be processed with conventional polishing techniques, or can only be very poorly processed. Due to the large differences in hardness, blurring or edge-rounding occurs, which distorts the original structure. In the application example shown, we are dealing with a solder ball structure. The goal was to determine the solder structure. The use of conventional grinding and polishing techniques was not possible due to the large differences in hardness between the solder ball and other materials in the sample.
    Read article
  • Cross Section of Solar Cells

    Application Note for Leica EM TIC020, Leica EM TIC 3X - Cross section of a complete solar cell.
    Read article
  • Cross Sectioning of a Multilayer System - Preparation of a Perfect Sample Surface for EBSD

    Application Note for Leica EM TIC 3X - Electron Backscattered Diffraction (EBSD) is a surface technique creating a diffraction pattern (Kikuchi-bands). It can be used for crystal orientation mapping, defect studies, phase identification, grain boundary studies and morphology studies. The information depth is just a few nm. Therefore good sample preparation is very important to avoid any damage. This is very difficult in case of multilayer system with big differences in hardness.
    Read article
  • High-Pressure Freezing and Freeze Substitution of Hep-2 Cells Infected with Chlamydia pneumoniae

    Application Note for Leica EM HPM100 - Hep-2 cells infected with Chlamydia pneumoniae were cultured on carbon-coated 6 mm Sapphire discs. Cells were high-pressure frozen in an EM HPM100 using the 6 mm CLEM middle plate with following setup: Sapphire disc with cells, spacer 200 μm, bare Sapphire disc, 2 spacers 200 μm. Ethanol was used as a synchronization fluid to transfer pressure at room temperature prior to cooling.
    Read article
  • Multilayer Systems with Widely Different Sputter Rates - Sample Preparation for TEM

    Application Note for Leica EM RES102 - The multi-layer system to be prepared in cross-section consists of a Si substrate, a TiN layer with a thickness of a few nm and a 500 nm W layer. All these components have extreme differences in their hardness, their atomic weight and in their sputter rates. A preparation of this kind of samples with sample rotation would lead to a wall overlying the area of the layers.
    Read article
  • In-Containing Compound Semiconductors - Sample Preparation for TEM

    Application Note for Leica EM RES102 - Previous studies showed that surface accumulation of In occurs when InP was milled in a conventional way with Ar ions. The consequence is In islands on the sample surface. This leads to low quality of TEM samples. To remove these islands, reactive ion milling with iodine ions (RIBE / CAIBE) can be used. This method has the disadvantage of polluting the ion guns and the vacuum system of the ion milling device and leads to chemical reactions with the sample material. To avoid these problems we prepared these samples very gently with low energy Ar ions.
    Read article
  • Carbon Coating for Polymeric Materials

    Application Note fo Leica EM ACE600 - A solid understanding of polymer property-structure relationships is critical to improve and shorten development routes to new products. A direct way to determine correlations between structure and mechanical properties is provided by electron microscopy. Electron microscopy techniques have an important advantage over other methods, as they can provide local information at high spatial resolution. However, a major problem with polymers is their inherent lack of contrast.
    Read article
  • High-Resolution Carbon Coating: How much Carbon is too much?

    Application Note for Leica EM ACE600 - Carbon support films are routinely used for high resolution TEM. Thickness is one of the main criteria to assess its usefulness for a particular experiment. Within that respect graphene (oxide) layers are frequently used. However, charge dissipation and mechanical stability towards high probe currents and high voltages, including long term acquisition protocols are equally important.
    Read article
  • Each Atom Counts: Protect Your Samples Prior to FIB Processing

    Application Note for Leica EM ACE600 - Focused ion beam (FIB) technology has become an indispensable tool for site-specific TEM sample preparation. It allows to extract electron transparent specimens with nanometer precision using a focused Ga+ ion beam.
    Read article
  • Commercially Available Hand Creams - Sample Preparation for Cryo-SEM

    Application Note for Leica EM HPM100 - Hand creams having different water contents were applied into the 100 μm cavities of two 3 mm type A sample carriers which were then closed cream sides inwards. The sample assembly was high pressure frozen with a Leica EM HPM100 and moved to a cooled Leica EM VCT100 loading station.
    Read article
  • "Shallow Trench Isolation" Structures - Sample Preparation for TEM

    Application Note for Leica EM RES102 - The cross-sectional preparation of structured semiconductor materials requires a very thorough mechanical pre-preparation. In doing this, it must be ensured that the structure of interest should be located as close to the centre of the sample as possible. As the sample will be ion milled from both sides, a specific preparation of the structure is necessary in most cases, which means that you must thin these structures from both sides.
    Read article
  • Tobacco Leaf - Critical Point Drying Protocol for SEM

    Application Note for Leica EM CPD300 - Critical point drying of tobacco leafs with subsequent platinum coating and SEM analysis.
    Read article
  • Paper Samples - Sample Preparation for SEM

    Application Note for Leica EM RES102 - A coated paper sample has been prepared with ion beam slope cutting in order to test the procedure with regard to its applicability. With the use of ion beam slope cutting a cross section of paper could be prepared. On the basis of this sample processing, it was possible to show the largely unaffected original structure of the thermally-sensitive paper in the scanning electron microscope.
    Read article
  • Metal Films and Sheets - Sample Preparation for TEM

    Application Note for Leica EM RES102 - Most metal films already have a thickness that requires no further mechanical pre-preparation. Frequently, however, they are also domed, which can lead to undefined milling angles. This is a disadvantage, particularly for films that contain inclusions, and that therefore mostly require very flat milling angles. Metal sheets are thicker than 100 µm. Mechanical pre-preparation is necessary to obtain an acceptable initial thickness and a good surface quality for ion milling.
    Read article
  • Nematode E. dianae - Critical Point Drying Protocol for SEM

    Application Note for Leica EM CPD300 - Critical point drying of nematode Eubostrichus dianae to detect the ectosymbiotic bacteria layer with subsequent gold coating ans SEM analysis.
    Read article
  • Visualization of Membrane Dynamics with Millisecond Temporal Resolution

    Application Note for Leica EM ICE, Leica EM AFS2 - Electrical stimulation of neurons combined with high-pressure freezing allows physiological activation of synaptic activity and precise control over the time frame of the induced synaptic activity.
    Read article
  • Cross-Sectional Preparation of Structured Semiconductor Materials for TEM

    Application Note for Leica EM RES102 - The vertical layer construction of a semiconductor structure should be examined as a TEM cross-sectional sample. In addition to the specific preparation of the desired structure, the widely different sputter rates and atomic weights of the individual components represent the level of difficulty involved with this preparation problem.
    Read article