개구수 AFC(적응형 초점 컨트롤)용에 적합 보정링(CORR) 커버글라스 사출동공 위치/DIC 프리즘 시야(단위) 이머전 타입 아이리스 다이어프램 배율 자유 작업 거리(단위 MM) 대물렌즈 타입 대물렌즈 타입
565056 HC PL APO EPI 0,7x/0,02 0.02 - - With & without - 25 건식 Without 0.7 7.2 PLAN APO
506228 HI PLAN 10x/0,25 0.25 - - With & without - 20 건식 Without 10 12 HI PLAN
506236 HI PLAN 40x/0,65 0.65 - - With - 20 건식 Without 40 0.35 HI PLAN
506241 HI PLAN 100x/1,25 OIL PH3 1.25 - - With - 20 오일 Without 100 0.10 HI PLAN
566069 HI PLAN EPI 10x/0,25 0.25 - - With & without - 20 건식 Without 10 12 HI PLAN
566071 HI PLAN EPI 5x/0,12 0.12 - - With & without - 20 건식 Without 5 11.7 HI PLAN
506424 HC PL APO 10x/0,40 CS2 0.4 AFC에 적합 - With A 25 건식 Without 10 2.56 PLAN APO
766018 HCX PL APO 150x/0,90 BD 0.9 - - Without C 25 건식 Without 150 0.2 PLAN APO
888763 HC PL APO EPI 0,7x/0,02 0.02 - - With & without - 25 건식 Without 0.7 7.2 PLAN APO
518149 20x/0,40 LIBS NUV 0.4 - - With & without - 16 건식 Without 20 4.1 LIBS
556511 HI PLAN 10x/0,25 POL DS 0.25 - - With & without - 20 건식 Without 10 12 HI PLAN
556512 HI PLAN 40x/0,65 POL DS 0.65 - - With - 20 건식 Without 40 0.36 HI PLAN
506386 HI PLAN 100x/0,80 0.8 - - With D 20 건식 Without 100 0.3 HI PLAN
506411 HC PL APO 10x/0,45 PH1 0.45 AFC에 적합 - With A 25 건식 Without 10 2.8 PLAN APO
506417 HC PL APO 93x/1,30 GLYC CORR STED WHITE 1.3 AFC에 적합 motCORR With - 25 GLYC Without 93 0.3 PLAN APO
506520 HC PL APO 50x/0,90 CRYO CLEM 0.9 - - Without C 25 건식 Without 50 0.28 PLAN APO
506298 N PLAN L 40x/0,55 CORR PH2 0.55 AFC에 적합 CORR With & without C 22 건식 Without 40 3.3 - 1.9 N PLAN
506536 HC FLUOTAR L 16x/0,60 IMM CORR DLS 0.6 - CORR With & without D 20 IMM incl BABB Without 16 2.50 PL FLUOTAR
507704 HC IRAPO L 25x/1,00 W motCORR 1 - motCORR With & without - 20 Without 25 2.6 HC IRAPO
507706 HC FLUOTAR L 16x/0,80 IMM CORR VISIR 0.8 - motCORR With & without - 20 IMM Without 16 8.15 HC FLUOTAR L VISIR
506362 HC APO L 63x/0,90 W U-V-I CS2 0.9 - - Without D 22 Without 63 2.2 HC APO L U-V-I CS2
506083 N PLAN 2,5x/0,07 0.07 - - With & without - 22 건식 Without 2.5 11.2 N PLAN
506367 HC PL FLUOTAR 40x/1,30 OIL 1.3 - - With E 22 오일 Without 40 0.15 PL FLUOTAR
506207 N PLAN 100x/1,25-0,60 OIL 1.25 - - With D 22 오일 0.6 100 0.12 N PLAN
556517 N PLAN EPI 10x/0,25 POL 0.25 - - With & without B 22 건식 Without 10 17.6 N PLAN
506214 HC PL FLUOTAR 150x/0,90 0.9 - - Without C 25 건식 Without 150 0.25 PL FLUOTAR
566036 N PLAN L 50x/0,50 0.5 - - Without C 22 건식 Without 50 8.2 N PLAN
506401 HI PLAN CY 10x/0,25 SL 0.25 - - With & without - 25 건식 Without 10 17.7 HI PLAN
566038 N PLAN L 50x/0,50 BD 0.5 - - Without C 22 건식 Without 50 8.1 N PLAN
506402 HI PLAN CY 10x/0,25 PH1 0.25 - - With & without - 25 건식 Without 10 17.7 HI PLAN
506217 HC PL FLUOTAR L 63x/0,70 CORR PH2 0.7 - CORR With C 25 건식 Without 63 2.6-1.8 PL FLUOTAR
566040 N PLAN H 50x/0,50 0.5 - - 1.8 Quartz - 22 건식 Without 50 7.1 N PLAN
506220 HC PL APO 100x/1,40-0,70 OIL 1.4 AFC에 적합 - With D 25 오일 0.7 100 0.09 PLAN APO
506404 HI PLAN CY 10x/0,25 0.25 - - With & without - 25 건식 Without 10 17.7 HI PLAN
506405 N PLAN 10x/0,25 0.25 - - With & without B 25 건식 Without 10 17.7 N PLAN
566047 N PLAN L 100x/0,75 0.75 - - Without B 22 건식 Without 100 3.5 N PLAN
506224 HC PL FLUOTAR 5x/0,15 0.15 - - With & without C 25 건식 Without 5 13.7 PL FLUOTAR
506226 HI PLAN 4x/0,10 0.1 - - With & without - 20 건식 Without 4 18 HI PLAN
506408 HI PLAN 4x/0,10 PH0 0.1 - - With & without - 25 건식 Without 4 13.9 HI PLAN
506227 HI PLAN 4x/0,10 SL 0.1 - - With & without - 20 건식 Without 4 18 HI PLAN
566056 N PLAN H 20x/0,40 0.4 - - 1.8 Quartz C 22 건식 Without 20 10.6 N PLAN
506229 HI PLAN 10x/0,25 SL 0.25 - - With & without - 20 건식 Without 10 12 HI PLAN
506230 HI PLAN 10x/0,25 PH 1 0.25 - - With & without - 20 건식 Without 10 12 HI PLAN
506234 HC PL FLUOTAR 1,6x/0,05 0.05 - - With & without - 25 건식 Without 1.6 3.4 PL FLUOTAR
506413 HC PL FLUOTAR 4x/0,13 PH0 0.13 - - With & without - 25 건식 Without 4 17 PL FLUOTAR
506237 HI PLAN 63x/0,75 0.75 - - With - 20 건식 Without 63 0.31 HI PLAN
506415 HC PL APO 40x/0,95 CORR PH2 0.95 AFC에 적합 CORR With C 25 건식 Without 40 0.17 PLAN APO
506238 HI PLAN 100x/1,25 OIL 1.25 - - With - 20 오일 Without 100 0.10 HI PLAN
506240 HI PLAN 40x/0,65 PH2 0.65 - - With - 20 건식 Without 40 0.36 HI PLAN
566070 HI PLAN EPI 20x/0,40 0.4 - - Without - 20 건식 Without 20 1.15 HI PLAN
506263 HI PLAN I 10x/0,22 0.22 - - With & without - 20 건식 Without 10 7.8 HI PLAN
506264 HI PLAN I 20x/0,30 0.3 - - With & without - 20 건식 Without 20 3 HI PLAN
506265 HI PLAN I 40x/0,50 0.5 - - With - 20 건식 Without 40 2 HI PLAN
506271 HI PLAN I 10x/0,22 PH1 0.22 - - With & without - 20 건식 Without 10 7.8 HI PLAN
506272 HI PLAN I 20x/0,30 PH1 0.3 - - With & without - 20 건식 Without 20 3 HI PLAN
506273 HI PLAN I 40x/0,50 PH2 0.5 - - With - 20 건식 Without 40 2 HI PLAN
506276 HI PLAN 20x/0,40 0.4 - - With - 20 건식 Without 20 0.92 HI PLAN
506277 HI PLAN 20x/0,40 SL 0.4 - - With & without - 20 건식 Without 20 0.92 HI PLAN
506278 HI PLAN 20x/0,40 PH1 0.4 - - With - 20 건식 Without 20 0.92 HI PLAN
581046 M PL APO MACRO 0.4x/0.014-0.003 0.014 - - With & without - 22 건식 0.003 0.4 60 PLAN APO
613240 PLAN 4x/0,10 0.1 - - With & without - 20 건식 Without 4 26.2 HI PLAN
613241 PLAN 10x/0,22 0.22 - - With & without - 20 건식 Without 10 7.8 HI PLAN
613242 PLAN 40x/0,65 0.65 - - With - 20 건식 Without 40 0.3 HI PLAN
613243 PLAN 100x/1,25 OIL 1.25 - - With - 18 오일 Without 100 0.10 HI PLAN
556060 HI PLAN 4x/0,10 POL 0.1 - - With & without - 20 건식 Without 4 18 HI PLAN
556061 HI PLAN 10x/0,25 POL 0.25 - - With & without - 20 건식 Without 10 12 HI PLAN
556065 HI PLAN 40x/0,65 POL 0.65 - - With - 20 건식 Without 40 0.36 HI PLAN
556066 HI PLAN 63x/0,75 POL 0.75 - - With - 20 건식 Without 63 0.31 HI PLAN
556071 HI PLAN 20x/0,40 POL 0.4 - - With - 20 건식 Without 20 0.92 HI PLAN
506369 HI PLAN I 40x/0,50 PH1 0.5 - - With - 20 건식 Without 40 2 HI PLAN
506399 HC FLUOTAR L 25x/0,95 W DLS 0.95 - - Without D 18 Without 25 2.5 PL FLUOTAR
506421 HC APO L 20x/0,50 W DLS 0.5 - - With & without D 22 Without 20 3.5 APO
506524 HC APO L 10x/0,30 W DLS 0.3 - - With & without D 20 Without 10 3.6 APO
581047 M PL APO MACRO 1x/0.035-0.006 0.035 - - With & without - 22 건식 0.006 1 60 PLAN APO
581048 M PL APO MACRO 2x/0.07-0.01 0.07 - - With & without - 22 건식 0.01 2 60 PLAN APO
581049 M PL APO MACRO 4x/0.14-0.03 0.14 - - With & without - 22 건식 0.03 4 60 PLAN APO
556023 N PLAN 50x/0,85 OIL POL XLR 0.85 - - With & without - 22 오일 Without 50 0.30 N PLAN
556068 HC PL FLUOTAR 20x/0,50 POL 0.5 - - Without D 25 건식 Without 20 1.27 PL FLUOTAR
506201 HC PL FLUOTAR L 40x/0,60 CORR 0.6 AFC에 적합 CORR With & without C 25 건식 Without 40 3.3-1.9 PL FLUOTAR
556515 HC PL FLUOTAR 40x/0,80 POL DS 0.8 - - With D 25 건식 Without 40 0.4 PL FLUOTAR
566073 N PLAN EPI 100x/0,85 0.85 - - Without D 22 건식 Without 100 0.33 N PLAN
566075 N PLAN EPI 100x/0,85 BD 0.85 - - Without D 22 건식 Without 100 0.33 N PLAN
767019 HCX PL APO 150x/0,95 0.95 - - Without C 25 건식 Without 150 0.2 PLAN APO
556074 N PLAN EPI 100x/0,85 POL 0.85 - - Without D 22 건식 Without 100 0.33 N PLAN
556085 HI PLAN EPI 20x/0,40 POL 0.4 - - Without - 22 건식 Without 20 1.15 HI PLAN
566077 N PLAN EPI 5x/0,12 BD 0.12 - - With & without B 22 건식 Without 5 14.0 N PLAN
566079 N PLAN EPI 40x/0,75 0.75 - - Without D 22 건식 Without 40 0.37 N PLAN
566081 N PLAN EPI 50x/0,75 XLF 0.75 - - Without D 22 건식 Without 50 1.50 N PLAN
506527 HC PL FLUOTAR 100x/1,32 -0,60 OIL 1.32 AFC에 적합 - With D 25 오일 0.6 100 0.18 PL FLUOTAR
566208 HC PL APO 50x/0,85 BD 0.85 - - Without C 25 건식 Without 50 0.34 PLAN APO
506534 HC PL FLUOTAR 5x/0,15 IMM DLS 0.15 - - With & without - 25 IMM incl BABB Without 5 4.80 PL FLUOTAR
566209 HC PL APO 100x/0,90 BD 0.9 - - Without C 25 건식 Without 100 0.2 PLAN APO
506314 N PLAN 40x/0,75 0.75 - - Without D 22 건식 Without 40 0.37 N PLAN
506321 N PLAN 50x/0,90 OIL 0.9 - - With & without - 22 오일 Without 50 0.14 N PLAN
506325 HC PL APO 100x/1,44 Oil CORR CS 1.44 AFC에 적합 CORR With D 25 오일 Without 100 0.10 PLAN APO
507901 ACS APO 40x/1,15 OIL CS 1.15 AFC에 적합 - With E 20 오일 Without 40 0.27 APO
581097 M PL APO MACRO 8x/0.22-0.03 0.22 - - With & without - 22 건식 0.03 8 44.6 PLAN APO
507902 ACS APO 10x/0,30 CS 0.3 AFC에 적합 - With & without C 20 건식 Without 10 3 APO
507904 ACS APO 20x/0,60 IMM CORR 0.6 - CORR With & without D 16 IMM Without 20 0.20 APO
518145 UVI 6,3x/0,13 MICRODISSECTION 0.13 - - With & without - 18 건식 Without 6.3 12.8 HI PLAN
888434 Optik Kit GSD 160x 1.43 AFC에 적합 CORR With C 25 오일 Without 160 0.07 PLAN APO
556078 HC PL FLUOTAR 50x/0,80 POL 0.8 - - Without C 25 건식 Without 50 1.04 PL FLUOTAR
556079 HC PL FLUOTAR 100x/0,90 POL 0.9 - - Without C 25 건식 Without 100 1.0 PL FLUOTAR
556083 N PLAN 20x/0,40 POL 0.4 - - With D 22 건식 Without 20 0.39 N PLAN
556084 N PLAN 40x/0,65 POL 0.65 - - With D 25 건식 Without 40 0.36 N PLAN
506209 HC PL FLUOTAR L 40x/0,60 CORR PH2 XT 0.6 - CORR With & without C 25 건식 Without 40 3.3-1.9 PL FLUOTAR
506400 HC FL PLAN 10x/0,25 0.25 - - With & without B 25 건식 Without 10 17.7 FL PLAN
506215 HC PL FLUOTAR 1,25x/0,04 T 0.04 - - With & without - 25 건식 Without 1.25 3.7 PL FLUOTAR
506216 HC PL FLUOTAR L 63x/0.70 CORR 0.7 - CORR With C 25 건식 Without 63 2.6-1.8 PL FLUOTAR
506403 HC FL PLAN 10x/0,25 PH1 0.25 - - With & without B 25 건식 Without 10 17.7 FL PLAN
566045 HC PL FLUOTAR 1,25x/0,04 R 0.04 - - Without - 25 건식 Without 1.25 1.6 PL FLUOTAR
506222 HC PL FLUOTAR L 63x/0,70 CORR XT 0.7 - CORR With C 25 건식 Without 63 2.6-1.8 PL FLUOTAR
566046 HC PL FLUOTAR 5x/0,15 BD 0.15 - - With & without C 25 건식 Without 5 13.0 PL FLUOTAR
506223 HC PL FLUOTAR 63x/0,90 CORR 0.9 - CORR With D 25 건식 Without 63 0.22 PL FLUOTAR
506406 N PLAN 10x/0,25 PH1 0.25 - - With & without B 25 건식 Without 10 17.7 N PLAN
566048 N PLAN L 100x/0,75 BD 0.75 - - Without B 22 건식 Without 100 3.5 N PLAN
566049 N PLAN L 20x/0,40 0.4 - - Without C 22 건식 Without 20 10.8 N PLAN
566051 N PLAN L 20x/0,40 BD 0.4 - - Without C 22 건식 Without 20 10.8 N PLAN
506409 L 1,6x/0,05 DLS 0.05 - - With & without - 16 건식 Without 1.6 8.1 -
566059 HC PL FLUOTAR 1.6x/0.05 0.05 - - With & without - 25 건식 Without 1.6 1.54 PL FLUOTAR
566062 HC PL FLUOTAR L 50x/0.55 0.55 - - Without C 25 건식 Without 50 8 PL FLUOTAR
506412 HC PL FLUOTAR 4x/0,13 0.13 - - With & without - 25 건식 Without 4 17 PL FLUOTAR
566063 HC PL FLUOTAR L 100x/0,75 0.75 - - Without - 25 건식 Without 100 4.7 PL FLUOTAR
566064 HC PL APO 50x/0,90 0.9 - - Without C 25 건식 Without 50 0.28 PLAN APO
566065 HC PL APO 100x/0,95 0.95 - - Without C 25 건식 Without 100 0.16 PLAN APO
566066 N PLAN EPI 20x/0,40 0.4 - - Without D 22 건식 Without 20 1.15 N PLAN
566067 N PLAN EPI 20x/0,40 BD 0.4 - - Without D 22 건식 Without 20 1.15 N PLAN
506418 HC PL FLUOTAR 63x/1.10 IMM CORR PH3 1.1 AFC에 적합 CORR With E 25 IMM Without 63 0.35 PL FLUOTAR
506419 HC PL FLUOTAR 63x/1.10 IMM CORR 1.1 AFC에 적합 CORR With E 25 IMM Without 63 0.35 PL FLUOTAR
506242 HC PL FLUOTAR L 20x/0,40 CORR 0.4 AFC에 적합 CORR With & without C 25 건식 Without 20 7.5-6.2 PL FLUOTAR
506243 HC PL FLUOTAR L 20x/0,40 CORR PH1 0.4 AFC에 적합 CORR With & without C 25 건식 Without 20 7.5-6.2 PL FLUOTAR
506247 N PLAN L 20x/0,35 0.35 AFC에 적합 - With & without - 22 건식 Without 20 6.9 N PLAN
566072 N PLAN EPI 50x/0,75 0.75 - - Without D 22 건식 Without 50 0.5 N PLAN
506248 N PLAN L 20x/0,35 PH1 0.35 AFC에 적합 - With & without - 22 건식 Without 20 6.9 N PLAN
566074 N PLAN EPI 50x/0,75 BD 0.75 - - Without D 22 건식 Without 50 0.5 N PLAN
506505 HC PL FLUOTAR 10x/0,30 0.3 AFC에 적합 - With & without D 25 건식 Without 10 11.0 PL FLUOTAR
566076 N PLAN EPI 5x/0,12 0.12 - - With & without B 22 건식 Without 5 14.0 N PLAN
506518 HC PL FLUOTAR 20x/0,55 PH2 0.55 AFC에 적합 - With D 25 건식 Without 20 1.2 PL FLUOTAR
506519 HC PL FLUOTAR 20x/0,55 0.55 AFC에 적합 - With D 25 건식 Without 20 1.2 PL FLUOTAR
566078 N PLAN EPI 40x/0,75 BD 0.75 - - Without D 22 건식 Without 40 0.37 N PLAN
506521 HC PL FLUOTAR 10x/0,32 0.32 AFC에 적합 - With D 25 건식 Without 10 11.13 PL FLUOTAR
506522 HC PL FLUOTAR 10x/0,32 PH1 0.32 AFC에 적합 - With D 25 건식 Without 10 11.13 PL FLUOTAR
566082 N PLAN EPI 10x/0,25 0.25 - - With & without B 25 건식 Without 10 17.7 N PLAN
506523 HC PL FLUOTAR 2,5x/0,07 0.07 - - With & without - 25 건식 Without 2.5 9.4 PL FLUOTAR
566083 N PLAN EPI 10x/0,25 BD 0.25 - - With & without B 25 건식 Without 10 16.1 N PLAN
506297 N PLAN L 40x/0,55 CORR 0.55 AFC에 적합 CORR With & without C 22 건식 Without 40 3.3 - 1.9 N PLAN
566200 HC PL FLUOTAR 50x/0,80 0.8 - - Without C 25 건식 Without 50 1.04 PL FLUOTAR
506525 HC PL FLUOTAR 100x/1,32 OIL 1.32 AFC에 적합 - With D 25 오일 Without 100 0.18 PL FLUOTAR
566201 HC PL FLUOTAR 50x/0,80 BD 0.8 - - Without C 25 건식 Without 50 1.04 PL FLUOTAR
506526 HC PL FLUOTAR 100x/1,32 OIL PH3 1.32 AFC에 적합 - With D 25 오일 Without 100 0.18 PL FLUOTAR
506302 N PLAN 5x/0,12 0.12 - - With & without B 22 건식 Without 5 14.0 N PLAN
566202 HC PL FLUOTAR 100x/0,90 0.9 - - Without C 25 건식 Without 100 1.0 PL FLUOTAR
506303 N PLAN 5x/0,12 PH0 0.12 - - With & without B 22 건식 Without 5 14.0 N PLAN
566203 HC PL FLUOTAR 100x/0,90 BD 0.9 - - Without C 25 건식 Without 100 1.0 PL FLUOTAR
506528 HC PL FLUOTAR 100x/1,32 OIL 1.32 - - Without D 25 오일 Without 100 0.27 PL FLUOTAR
506304 HC FL PLAN 2,5x/0,07 0.07 - - With & without - 25 건식 Without 2.5 11.2 FL PLAN
506529 HC PL APO 20x/0,80 0.8 AFC에 적합 - With C 25 건식 Without 20 0.4 PLAN APO
506305 HC FL PLAN 5x/0,12 0.12 - - With & without B 25 건식 Without 5 14.0 FL PLAN
566205 HC PL APO 150x/0,90 BD 0.9 - - Without C 25 건식 Without 150 0.25 PLAN APO
506530 HC PL APO 20x/0,80 PH2 0.8 AFC에 적합 - With C 25 건식 Without 20 0.4 PLAN APO
506308 HC FL PLAN 20x/0,40 0.4 - - With D 25 건식 Without 20 0.39 FL PLAN
566206 HC PL FLUOTAR L 20x/0,40 BD 0.4 - - Without C 25 건식 Without 20 11.1 PL FLUOTAR
506531 HC PL FLUOTAR 100x/0,95 CORR 0.95 - CORR With D 25 건식 Without 100 0.23 PL FLUOTAR
506309 HC FL PLAN 20x/0,40 PH1 0.4 - - With D 25 건식 Without 20 0.39 FL PLAN
566207 HC PL FLUOTAR L 50x/0,55 BD 0.55 - - Without C 25 건식 Without 50 8.1 PL FLUOTAR
506310 HC FL PLAN 40x/0,65 0.65 - - With D 25 건식 Without 40 0.36 FL PLAN
506311 HC FL PLAN 40x/0,65 PH2 0.65 - - With D 25 건식 Without 40 0.36 FL PLAN
506312 HC FL PLAN 100x/1,25 OIL 1.25 - - With D 25 오일 Without 100 0.13 FL PLAN
566500 HC PL FLUOTAR 20x/0,50 0.5 - - Without D 25 건식 Without 20 1.27 PL FLUOTAR
506313 HC FL PLAN 100x/1,25 OIL PH3 1.25 - - With D 25 오일 Without 100 0.13 FL PLAN
566503 HC PL FLUOTAR 10x/0,30 BD 0.3 - - With & without D 25 건식 Without 10 11.0 PL FLUOTAR
566509 HC PL FLUOTAR 20x/0,45 BD 0.45 - - Without C 25 건식 Without 20 3.0 PL FLUOTAR
506318 HC PL APO 100x/1,47 OIL CORR TIRF 1.47 AFC에 적합 CORR With D 25 오일 Without 100 0.10 PLAN APO
506319 HC PL APO 63x/1,47 OIL CORR TIRF 1.47 AFC에 적합 CORR With E 25 오일 Without 63 0.1 PLAN APO
507900 ACS APO 63x/1,30 OIL CS 1.3 AFC에 적합 - With E 16 오일 Without 63 0.16 APO
506329 HC PL APO 40x/1,30 OIL 1.3 AFC에 적합 - With D 25 오일 Without 40 0.22 PLAN APO
506342 HC PL APO 40x/1,10 W CORR 1.1 AFC에 적합 CORR With E 25 Without 40 0.63 PLAN APO
518146 UVI 5x/0,12 MICRODISSECTION 0.12 - - With & without - 20 건식 Without 5 11.7 HI PLAN
518147 UVI 10x/0,25 MICRODISSECTION 0.25 - - With & without A 22 건식 Without 10 2.9 HI PLAN
518148 UVI 2,5x/0,07 MICRODISSECTION 0.07 - - With & without - 22 건식 Without 2.5 11.7 HI PLAN
506349 HC PL APO 63x/1,40-0,60 OIL 1.4 AFC에 적합 - With E 25 오일 0.6 63 0.14 PLAN APO
556036 N PLAN 2,5x/0,07 POL 0.07 - - With & without - 20 건식 Without 2.5 11.2 N PLAN
556053 N PLAN 100x/1,25 OIL POL 1.25 - - With & without D 22 오일 Without 100 0.12 N PLAN
556056 N PLAN 63x/0,80 POL 0.8 - - With D 22 건식 Without 63 0.26 N PLAN
556058 HC PL FLUOTAR 5x/0,15 POL 0.15 - - With & without C 25 건식 Without 5 13.7 PL FLUOTAR
556072 N PLAN EPI 20x/0,40 POL 0.4 - - Without D 22 건식 Without 20 1.15 N PLAN
506365 HC PL FLUOTAR (340) 40x/1,30 OIL 1.3 - - With E 22 오일 Without 40 0.15 PL FLUOTAR
556073 N PLAN EPI 50x/0,75 POL 0.75 - - Without D 22 건식 Without 50 0.5 N PLAN
506096 N PLAN 20x/0,40 0.4 - - With D 22 건식 Without 20 0.39 N PLAN
506368 HC FLUOTAR (340) 100x/1,30 OIL 1.3 - - With D 22 오일 Without 100 0.14 HC FLUOTAR
506097 N PLAN 40x/0,65 0.65 - - With D 22 건식 Without 40 0.36 N PLAN
556075 N PLAN EPI 5x/0,12 POL 0.12 - - With & without B 22 건식 Without 5 14.0 N PLAN
506098 N PLAN 20x/0,40 PH1 0.4 - - With - 22 건식 Without 20 0.39 N PLAN
556076 N PLAN EPI 20x/0,40 OIL POL XLR 0.4 - - Without C 22 오일 Without 20 0.23 N PLAN
506371 HC PL FLUOTAR (340) 20x/0,80 OIL 0.8 - - With C 25 오일 Without 20 0.19 PL FLUOTAR
506099 N PLAN 40x/0,65 PH2 0.65 - - With D 22 건식 Without 40 0.36 N PLAN
506148 HC APO L 63x/0,90 W U-V-I 0.9 - - Without D 22 Without 63 2.2 APO
506379 HC PL FLUOTAR L 100x/0,85 CORR 0.85 - CORR With & without B 25 건식 Without 100 1.1 PL FLUOTAR
506158 N PLAN 100x/1,25 OIL 1.25 - - With & without D 22 오일 Without 100 0.12 N PLAN
556087 HC PL FLUOTAR 40x/0,80 POL 0.8 - - With D 25 건식 Without 40 0.4 PL FLUOTAR
506381 HC PL APO 100x/1,40 OIL PH3 1.4 AFC에 적합 - With D 25 오일 Without 100 0.09 PLAN APO
506159 N PLAN 100x/1,25 OIL PH3 1.25 - - With & without D 22 오일 Without 100 0.12 N PLAN
506382 HC PL FLUOTAR 40x/0,80 0.8 AFC에 적합 - With D 25 건식 Without 40 0.4 PL FLUOTAR
506184 N PLAN 63x/0,80 0.8 - - With D 22 건식 Without 63 0.26 N PLAN
556501 HC PL FLUOTAR 20x/0,50 POL 0.5 AFC에 적합 - With D 25 건식 Without 20 1.15 PL FLUOTAR
506383 HC PL FLUOTAR 40x/0,80 PH2 0.8 AFC에 적합 - With D 25 건식 Without 40 0.4 PL FLUOTAR
556503 HC PL FLUOTAR 10x/0,30 POL 0.3 AFC에 적합 - With & without D 25 건식 Without 10 11.0 PL FLUOTAR
506384 HC PL FLUOTAR 63x/1,30 OIL 1.3 AFC에 적합 - With E 24 오일 Without 63 0.16 PL FLUOTAR
506203 HC PL FLUOTAR L 40x/0,60 CORR PH2 0.6 AFC에 적합 CORR With & without C 25 건식 Without 40 3.3-1.9 PL FLUOTAR
506385 HC PL FLUOTAR 63x/1,30 OIL PH3 1.3 AFC에 적합 - With E 24 오일 Without 63 0.16 PL FLUOTAR
506208 HC PL FLUOTAR L 40x/0.60 CORR XT 0.6 - CORR With & without C 25 건식 Without 40 3.3-1.9 PL FLUOTAR
506398 HC PL APO 63x/1,30 GLYC CORR 1.3 AFC에 적합 CORR With D 25 GLYC Without 63 0.30 PLAN APO
506407 HC PL APO 10x/0,40 CS2 0.4 AFC에 적합 - With A 25 건식 Without 10 2.74 PLAN APO
506422 HC PL APO 40x/1,25 GLYC CORR CS2 1.25 AFC에 적합 CORR With E 24 GLYC Without 40 0.35 PLAN APO
506517 HC PL APO 20x/0,75 CS2 0.75 AFC에 적합 - With C 25 건식 Without 20 0.62 PLAN APO
506533 HC FLUOTAR L 16x/0,60 IMM CORR VISIR 0.6 AFC에 적합 CORR With & without D 20 IMM incl BABB Without 16 2.50 HC FLUOTAR L VISIR
507701 HC APO L 20x/1,00 W 1 - - Without H 20 Without 20 1.95 APO
507702 HC APO L 20x/0.95 IMM 0.95 - - Without H 20 IMM incl BABB Without 20 1.95 APO
507703 HC FLUOTAR L 25x/1,0 IMM (ne=1,457) motCORR VISIR 1 - motCORR With & without - 20 IMM Without 25 6 HC FLUOTAR L VISIR
506343 HC PL APO 20x/0,75 IMM CORR CS2 0.75 AFC에 적합 CORR With & without C 25 IMM Without 20 0.66 PLAN APO
506344 HC PL IRAPO 20x/0,75 W 0.75 - - With & without - 25 Without 20 0.67 PLAN APO
506346 HC PL APO 63x/1,20 W CORR CS2 1.2 AFC에 적합 CORR With E 25 Without 63 0.30 PLAN APO
506350 HC PL APO 63x/1,40 OIL CS2 1.4 AFC에 적합 - With E 25 오일 Without 63 0.14 PLAN APO
506351 HC PL APO 63x/1,40 OIL PH3 CS2 1.4 AFC에 적합 - With E 25 오일 Without 63 0.14 PLAN APO
506352 HC PL IRAPO 40x/1,10 W CORR 1.1 - CORR With - 25 Without 40 0.65 PLAN APO
506353 HC PL APO 63x/1,30 GLYC CORR CS2 1.3 AFC에 적합 CORR With D 25 GLYC Without 63 0.30 PLAN APO
506356 HC PL APO 63x/1,20 W CORR CS2 1.2 - CORR Without E 25 Without 63 0.30 PLAN APO
506357 HC PL APO 40x/1,10 W CORR CS2 1.1 AFC에 적합 CORR With E 25 Without 40 0.65 PLAN APO
506358 HC PL APO 40x/1,30 OIL CS2 1.3 AFC에 적합 - With D 25 오일 Without 40 0.24 PLAN APO
506359 HC PL APO 40x/1,30 OIL PH3 CS2 1.3 AFC에 적합 - With D 25 오일 Without 40 0.24 PLAN APO
506360 HC PL APO 40x/1,10 W motCORR CS2 1.1 AFC에 적합 motCORR With E 25 Without 40 0.65 PLAN APO
506361 HC PL APO 63x/1,20 W motCORR CS2 1.2 AFC에 적합 motCORR With E 25 Without 63 0.30 PLAN APO
506372 HC PL APO 100x/1,40 OIL CS2 1.4 AFC에 적합 - With D 25 오일 Without 100 0.13 PLAN APO
506142 HC APO L 10x/0,30 W U-V-I 0.3 - - With & without D 20 Without 10 3.6 APO
506374 HC FLUOTAR L 25x/0,95 W VISIR 0.95 - - Without D 18 Without 25 2.5 HC FLUOTAR L VISIR
506147 HC APO L 20x/0,50 W U-V-I 0.5 - - With & without D 22 Without 20 3.5 APO
506375 HC FLUOTAR L 25x/0,95 W VISIR 0.95 AFC에 적합 - With D 18 Without 25 2.4 HC FLUOTAR L VISIR
506378 HC PL APO 100x/1,40 OIL STED WHITE 1.4 AFC에 적합 - With D 25 오일 Without 100 0.13 PLAN APO
506155 HC APO L 40x/0,80 W U-V-I 0.8 - - Without D 22 Without 40 3.3 APO
566204 HC PL APO 150x/0,90 IVIS BD 0.9 - - Without C 25 건식 Without 150 0.25 PLAN APO
506410 HC PL APO 10x/0,45 0.45 AFC에 적합 - With A 25 건식 Without 10 2.8 PLAN APO
506414 HC PL APO 40x/0,95 CORR 0.95 AFC에 적합 CORR With C 25 건식 Without 40 0.17 PLAN APO
506355 HC PL APO 63x1,2 W CORR UVIS CS2 1.2 AFC에 적합 CORR With D 25 Without 63 0.22 PLAN APO
506333 HC PL APO 86x/1,20 W motCORR STED white 1.2 AFC에 적합 motCORR With - 25 Without 86 0.3 PLAN APO
506423 HC PL APO 40x/1,25 GLYC motCORR CS2 1.25 AFC에 적합 motCORR With E 24 GLYC Without 40 0.35 PLAN APO