Kontakt
Leica EM CPD300 Critical Point Dryer Sample Preparation for Electron Microscopy Products Home Leica Leica Microsystems

Automatisierter Kritisch-Punkt-Trockner Leica EM CPD300

  • Micro-CT of Insect Larva Protocol

    Species: red blood worm (midge larva) Critical point drying of midge larvae with subsequent X-ray micro-computed tomography (micro-CT) to reconstruct the inner anatomy.
    Read article
  • Tobacco Leaf - Critical Point Drying Protocol for SEM

    Application Note for Leica EM CPD300 - Critical point drying of tobacco leafs with subsequent platinum coating and SEM analysis.
    Read article
  • Nematode E. dianae - Critical Point Drying Protocol for SEM

    Application Note for Leica EM CPD300 - Critical point drying of nematode Eubostrichus dianae to detect the ectosymbiotic bacteria layer with subsequent gold coating ans SEM analysis.
    Read article
  • Wall Cress Pod Protocol - Critical Point Drying of Arabidopsis thaliana for SEM

    Application Note for Leica EM CPD300 - Critical point drying of wall cress (Arabidopsis thaliana) pod with subsequent gold coating and SEM analysis.
    Read article
  • Bacteria Protocol - Critical Point Drying of E. coli for SEM

    Application Note for Leica EM CPD300 - Critical point drying of E. coli with subsequent platinum / palladium coating and SEM analysis. Sample was inserted into a filter disc (Pore size: 16 - 40 μm)…
    Read article
  • Clawed Frog Nuclear Envelope Protocol

    Application Note for Leica EM CPD300 - Critical point drying of nuclear pores from clawed frog oocytes with subsequent chromium coating and SEM analysis. Silicon chips containing the samples were…
    Read article
  • Micro-Computed Tomography (micro-CT) of Insect Brain Protocol

    Application Note for Leica EM CPD300 - Critical point drying of the blow fly with subsequent X-ray micro-computed tomography (micro-CT) to detect neuroanatomical features.
    Read article
  • Micro-Computed Tomography (micro-CT) of Book Scorpion Musculature

    Application Note for Leica EM CPD300 - Critical point drying of book scorpion with subsequent X-ray micro-computed tomography (micro-CT) to detect anatomical features with special regard to the…
    Read article
  • Wrinkled Giant Hyssop Leaf Protocol

    Application Note for Leica EM CPD300 - Critical point drying of wrinkled giant hyssop leaf with subsequent gold coating and SEM analysis.
    Read article
  • Black Mould Protocol

    Application Note for Leica EM CPD300 - Critical point drying of Black mould (Aspergilus niger) with subsequent platinum / palladium coating and SEM analysis to detect conidiospores. Sample was…
    Read article
  • Water Flea Protocol

    Application Note for Leica EM CPD300 - Critical point drying of water flea with subsequent gold coating and SEM-Analysis to detect finde surface structures.
    Read article
  • Human Blood Cells Protocol

    Application Note for Leica EM CPD300 - Life Science Research. Species: Human (Homo sapiens) Critical point drying of human blood with subsequent platinum / palladium coating and SEM analysis.
    Read article
  • Critical-point Drying for the Preparation of Biological Samples for MicroCT Analysis

    X-ray micro-computed tomography (micro-CT) is a routinely applied non-invasive technique for the investigation of the internal anatomy and morphology of organisms. As a result of a micro-CT scan a…
    Read article
  • Brief Introduction to Critical Point Drying

    One of the uses of the Scanning Electron Microscope (SEM) is in the study of surface morphology in biological applications which requires the preservation of the surface details of a specimen. Samples…
    Read article