Ion Beam Milling

Ion Beam Milling Systems

When material specimen surfaces are prepared for SEM or incident light microscopy, the specimen usually undergoes multiple processes until the layer or surface to be analyzed is machined with precision. Leica Microsystems’ workflow solutions for solid state technology cover all steps required for demanding high-quality sample preparation.

Need Assistance?

Contact our team of experts to help you simplify your EM sample preparation.

Simplify your EM Sample Preparation with workflow solutions by Leica Microsystems!

While the Leica EM TXP unites all steps of pre-preparation in one instrument, the Leica EM TIC 3X carries out the final, high quality surface finishing for almost any material. Connecting with the Leica EM VCT docking configuration, the sample can then be transferred into the (cryo) SEM under optimal conditions.

Enhanced Resolution with Ion Beam Milling

The Ion Beam Milling technique, also known as Ion Beam Etching, is used to achieve a well-prepared sample surface quality for high resolution imaging and analysis. It removes residual artefacts from mechanical cutting and polishing. The ion polished cross-sections and planar samples prepared by Ion Beam Etching can be used for electron microscopy imaging as well as microstructural analysis applications such as EDS, WDS, Auger and EBSD.

The EM TIC 3X Milling Machine offers triple ion beams that speed up the preparation process significantly and achieve to reveal finest details and structures on sample surfaces. Watch the video and see how to cut the preparation time for IC gold wire bonding using the Target Surfacing System EM TXP and the EM TIC 3X Ion Beam Milling System.

ion beam milling related articles

Read our latest articles about Ion Beam Milling

The knowledge portal of Leica Microsystems offers scientific research and teaching material on the subjects of microscopy. The content is designed to support beginners, experienced practitioners and scientists alike in their everyday work and experiments.

MORE ARTICLES

Electric car or EV car charging in station. Eco-friendly alternative energy concept.

Alternative Fuels and Why Sustainable Solutions are Important

This free on-demand webinar is about the role of alternative fuel vehicles and why sustainable solutions are of increasing importance to the automotive industry.
Electric car - generic 3d rendering

Technical Cleanliness in the Automotive Industry for Electromobility

This free on-demand webinar covers the increasing focus on technical cleanliness in the automotive industry for electromobility and the VDA 19.1 revision.
Optical microscope image of salt contamination on an aluminum/silicon (Al/Si) surface. Credit: Gerweck GmbH, Germany.

Microscopic Defects in Electroplating

This free on-demand webinar shows how to identify quickly root causes of defects during electroplating of components with optical microscopy and LIBS (laser spectroscopy).
User analyzing particles and fibers on a filter for cleanliness analysis with the DM6 M LIBS 2-methods-in-1 solution.

Basics in Component Cleanliness Analysis

An overview on the basics of component cleanliness and analysis solutions that can be tailored to your specific needs is presented. For the automotive industry, obtaining results rapidly, accurately,…

3 Factors Determine the Damage Potential of Particles

This article discusses the 3 factors for determining the potential of a particle to cause damage to parts and components in the automotive and electronic industry. These factors include the…

Cleanliness Analysis with a 2-Methods-in-1 Solution

In this article, it is examined how an overall efficient and cost-effective cleanliness analysis workflow can be achieved with a 2-methods-in-1 materials analysis solution, combining optical…
The various solutions from Leica Microsystems for cleanliness analysis.

Factors to Consider for a Cleanliness Analysis Solution

Choosing the right cleanliness analysis solution is important for optimal quality control. This article discusses the important factors that should be taken into account to find the solution that best…
Type of contamination: spores

Cleanliness Analysis for Particulate Contamination

Devices, products, and their components fabricated in many industries can be quite sensitive to contamination and, as a result, have stringent requirements for technical cleanliness. Measurement…
Particles and fibers on a filter which will be counted and analyzed for cleanliness

Efficient Particle Counting and Analysis

This report discusses particle counting and analysis using optical microscopy for cleanliness of parts and components. Particle counting and analysis is a critical part of quality assurance in the…
When particulate contamination is present in lubricating fluids or oils, it can cause damage to parts or components leading to malfunctions.

Hydraulics in the Automotive and Aerospace Industries

Cleanliness standards relating to lubricants, hydraulic fluids, and oils, e.g., ISO 4406 and DIN 51455 are discussed in this article. Cleanliness plays a central role in the automotive and…

Cutting and Polishing

Preparation often begins with a need to accurately cut, grind and polish the surface prior to ion beam milling and metal/carbon coating. With the Leica EM TXP target preparation system all required machining steps can be completed in one instrument – from diamond cutting and milling to polishing.

High quality surfacing

The unique broad ion beam milling system of the Leica EM TIC 3X is the system of choice for EDS, WDS, Auger and EBSD, because ion beam milling is often found to be the only method capable of achieving high quality cross-sections and planed surfaces of almost any material. The process reveals the internal structures of a sample whilst minimizing deformation or damage.

Sputter Coater & Freeze Fracture Solutions

Sputter Coater & Freeze Fracture Solutions

To obtain high-quality images of samples with scanning (SEM) or transmission electron microscopy (TEM), your samples need to be conductive to avoid charging. If a sample does not have a high enough conductivity, then you can quickly cover it with a conductive layer using the method of sputter coating. Also, a carbon or e-beam evaporator coating can be used. Such coatings protect the sample, allow enhancing of the EM image contrast, or can act as a TEM-grid support film for small scale samples.

Read More

 Due to the open chamber design and continuous gas exchange the SampLink chambers keep live cells healthy

Cryo Preparation Systems

High pressure freezing is often the preferred method for preserving aqueous samples in their close-to-native state, as it captures the intricate changes in fine structure or cellular dynamics. Leica Microsystems combines high pressure freezing with light stimulation or electrical stimulation: It enables you to visualize highly dynamic processes or the structural changes of samples at a nanometer resolution and with millisecond precision.

Read More

Overview of Drosophila gastric caeca and a mitochondrion with well-defined cristae and well-preserved surrounding membranes. Micrographs courtesy of Dr. Syed (NIH/NIDCR) and Dr. Bleck (NIH/NHLBI)

Ultramicrotomes & Cryo-Ultramicrotomes

Whether tissue sample, polymer, rubber, metals or nanoparticles, Leica ultramicrotomes provide extremely thin sections and perfect surface quality in a wide range of applications. From materials science to cancer research, our ultramicrotomes are used for many different kinds of research and quality control all over the world. 

Read More

Sputter Coater & Freeze Fracture Solutions
 Due to the open chamber design and continuous gas exchange the SampLink chambers keep live cells healthy
Overview of Drosophila gastric caeca and a mitochondrion with well-defined cristae and well-preserved surrounding membranes. Micrographs courtesy of Dr. Syed (NIH/NIDCR) and Dr. Bleck (NIH/NHLBI)

Interested to know more?

Talk to our experts. We are happy to answer all your questions and concerns.

Contact Us

Do you prefer personal consulting? Show local contacts

Scroll to top